00196624-04_Service Manual WPC5_6_EN_01-2019 - 第109页

Service Ma nual W PC5 / WPC6 Removal / Install ation The s ensor for t he s afety fla p whe n ope n is loca t ed on the u nders id e of the bas e pla te . See als o … . 3.5 .1. 4 Loosen the T ension of the Load Axis Driv…

100%1 / 143
Service Manual WPC5 / WPC6
3.7.17 Sensor 16 NSM module (WPC6) Safety Sensor for the Hand Guard
Spare Part
Safety sensor hand guard [03056990-xx]
Preparations
Loosen the tension of the load axis
drive belt (2) at the tensioning
screw behind the tower (1).
Loosen the screws fixing the motor
to the base plate at (3).
Lift off the base plate and turn it
over.
Service Manual WPC5 / WPC6
Removal / Installation
The sensor for the safety flap when open is located on the underside of the base plate.
See also.
3.5.1.4
Loosen the Tension of the Load Axis Drive Belt [ 3-33]
3.5.6
Setting the Load Axis Belt Tension [
3-43]
Disconnect connector X7 for the
safety flap when open from the
circuit board.
Remove the two screws fastening
the sensor (1).
Insert the new sensor and fix into
place with the two screws.
Reconnect connector X7 to the
circuit board.
Service Manual WPC5 / WPC6
3.7.18 Lading flap close magnet
Spare Parts
Lading flap close magnet [03083123-xx]
Removal / Installation
The holding magnet is mounted on a pedestal (1) in the NSM panel with 3 "NB602 M4x8"
screws [03005643].
The 3 screws can be accessed from the outside through a hole in the underside of the panel
(2).
The magnet has a 20 cm long cable with a 2 pin plug firmly attached.
The magnet is plugged into connector X30a on the back of the "backplane control
module" via the "cable: holding magnet loading flap" [03083109-01].
The adjustment with respect to the distance of the magnet to the loading door via the
"magnetic plate", which is mounted on the tailgate.
1
2
Attention: Do not clamp the cable!
Lead the cable through the notch on
the magnet.