Service Ma nual W PC5 / WPC6 4.1.3 Reference Proximity Switch (Bero) ➢ Remove al l waffle-pack tray c arriers (WPTC) from the WPC. ➢ Select the l ifting axis (1). ➢ Select the fu nction (2). ➢ Select (3). ➢ Confirm the n…

100%1 / 143
Service Manual WPC5 / WPC6
Use the arrow keys (2) to select the required pitch (1) (0.1 mm in this example).
Use the arrow keys to move the tower so that the tray can be correctly moved from the feed
axis into the tower.
Continue with (3).
Follow the instruction shown and confirm the changes made with .
Service Manual WPC5 / WPC6
4.1.3 Reference Proximity Switch (Bero)
Remove all waffle-pack tray carriers (WPTC) from the WPC.
Select the lifting axis (1).
Select the function (2).
Select (3).
Confirm the new reference point proximity switch with .
Service Manual WPC5 / WPC6
4.1.4 Calibrating the Limit Switch
The plus and minus position of the limit switches need to be calibrated.
Remove all waffle-pack tray carriers (WPTC) from the WPC.
Select the lifting axis (1).
Select the function - (2).
Select (3).
Calibrating the limit switch -
Confirm the new position at which the limit switch triggers with .
Calibrating the limit switch +
Select the lifting axis (1).
Select the function and continue with the same procedure as that
used for calibrating the limit switch.