00196624-04_Service Manual WPC5_6_EN_01-2019 - 第138页

Service Ma nual W PC5 / WPC6 ➢ Confirm the n ew position at which the limit switch triggers with (1). Calibrating the limit sw itch + ➢ Select the l ifting axis (1). ➢ Select the func tion a nd continue with the sa me pr…

100%1 / 143
Service Manual WPC5 / WPC6
4.3.3 Calibrating the Limit Switch
The plus and minus position of the limit switches need to be calibrated.
Calibrating the limit switch -
Select the load axis (1).
Select the function (2).
Select (3).
Follow the instruction shown and continue with (1).
Service Manual WPC5 / WPC6
Confirm the new position at which the limit switch triggers with (1).
Calibrating the limit switch +
Select the lifting axis (1).
Select the function and continue with the same procedure as that
used for calibrating the limit switch.
Service Manual WPC5 / WPC6
4.4 Performing a WPC Endurance Run
After calibration, we recommend that you test the function by performing a WPC endurance run.
Select .
Set a continuous run of 15 mins and start.