Service Ma nual W PC5 / WPC6 4.4 Performing a WPC Endurance Run After calibration, we rec omm end that you test the function b y perform ing a W PC endur ance run. ➢ Select . ➢ Set a continuous run of 15 mins and start.

Service Manual WPC5 / WPC6
➢ Confirm the new position at which the limit switch triggers with (1).
Calibrating the limit switch +
➢ Select the lifting axis (1).
➢ Select the function and continue with the same procedure as that
used for calibrating the limit switch.

Service Manual WPC5 / WPC6
4.4 Performing a WPC Endurance Run
After calibration, we recommend that you test the function by performing a WPC endurance run.
➢ Select .
➢ Set a continuous run of 15 mins and start.

Service Manual WPC5 / WPC6
4.5 Storing and Restoring Machine Data
Storing machine data
➢
Log in as .
➢ Select (1) => .
➢ Select the relevant location (2).
➢ Select the option (3).
➢ Enter the WPC serial number (4) and select .
➢ Select (5).
⇨ A dialog box for the machine data storage location will open.
➢ Enter the required storage location and then save the machine data..