00196624-04_Service Manual WPC5_6_EN_01-2019 - 第97页

Service Ma nual W PC5 / WPC6 Settings ➢ Check the fu nction and correct positio n of the limit swit ch. The limit switch mus t switch when the lifting axis moves o ver the switch (3) ( end position). ➢ To do this, open t…

100%1 / 143
Service Manual WPC5 / WPC6
3.7.10 Sensor 5 Bottom lifting axis limit switch
Spare Part
Bottom lifting axis limit switch [03047280-01]
Removal / Installation
Move the lifting axis upwards into the refill position. The limit switch is located in the frame,
under the lifting axis.
Remove the front cover (on the lifting axis drive motor). You can now access the opening for
the limit switch connection cable.
Mark the exact position of the limit switch.
Loosen the two fastening screws (1) on the limit switch.
Remove the fixture plate (4).
Loosen the cable clamps and remove the cable ties.
Unthread the connection cable as far as the control unit back plane and unplug it from the
terminal strip.
Fit the new limit switch with fixture plate (4) at the marked installation position.
Align the limit switch parallel to the stopper edge (2).
Restore the electrical connection and fix the connection cable into place.
Service Manual WPC5 / WPC6
Settings
Check the function and correct position of the limit switch. The limit switch must switch when
the lifting axis moves over the switch (3) (end position).
To do this, open the following function in the main view:
.
Select the button in the Axis input area.
Select the + button in the input area (see also "4.1.4 Calibrating the Limit Switch"
[ 4-119]).
The lifting axis will be moved so that an actuator on the lifting axis moves over the limit
switch.
The limit (end position) will be calculated.
Go to the main view and open the menu function
.
Make sure that the view option is enabled.
A dialog box will open and the calculated value will be shown. The permissible limits
(minimum/maximum position) will also be shown. The end position must be within these
limits.
Check the permissible limits against the value actually measured.
If necessary, correct the mechanical position of the limit switch and repeat the
measurement procedure.
If the value is within the permissible limits, save the data by clicking on .
Seal the two mounting bracket fastening screws with locking varnish.
Service Manual WPC5 / WPC6
3.7.11 13 Safety Switch
Spare Part
Safety switch, closed (safety switch with cable) [03062919-xx]
Removal / Installation
Mark the installation position of the safety switch (1) at the two fastening screws (2) with
slots.
Loosen the two fastening screws (2) and remove the safety switch (1).
Unthread the connection cable (3) as far as the control unit back plane..
The connection cable has two separate connections:
Unplug the connection cable at terminal strip x12a on the control unit back plane.
Unplug the connection cable from the safety loop.
Fit the new safety switch at the marked installation position.
Restore the electrical connection and fix the connection cable into place.
Settings
Make sure that the door contact engages properly. If necessary, correct the installation
position at the slots.
Check that the safety switch switches reliably at the docked WPC.