Objective 31: Calibrate the Camera Reference Position using Technical Reference
Manual
TRS Advanced Maintenance
102
Issue 2, Nov 14
Objective 32: Calibrate Vision Height:
Vision Height is measured from the_________________________________________ to the
_______________________________________________.
This is adjusted by______________________________________.
The measurement should be_______________________________.
Use TRS Technical Reference Manual to complete the Vision Height Setting on the machine:
Issue 2, Nov 14
TRS Advanced Maintenance
103
Objective 33: Calibrate Print Height:
NOTE
Do not fit the 212272 Shim for this procedure. It is easier to see screen deformation.
1. Load the screen to the printer.
2. In Diagnostics, select Set Reference Print Height from the Rising Table module.
3. Adjust the print height using INCR/DECR & MOVE until the Rail Cap foils are seen to
slightly deform the screen.
4. Adjust the Rising Table back down until the Rail Cap Foils are clear of the screen.
NOTE
The gap between screen & foils should be AS SMALL AS POSSIBLE.
Fine tune the height by jogging the Table UP & DOWN until a single jog is
enough to visibly DEFORM or UNDEFORM the screen.
5. Select SET Height and save the setting to the configuration file.
6. HOME the Rising Table.
7. Drive the Rising Table to PRINT Height (to confirm the height setting).
8. HOME the Rising Table again.
9. UNLOAD the Calibration Screen.