TRS Advanced WB Intel Issue 02 - 第12页
TRS Advanced Maintenance 12 Issue 2, Nov 14 Objective 6: Identify Node 19 board and explain its function. Use the TRS electrical drawing to complete the box below Connecto r Function N19PL1 N19PL2 N19PL3 N19SK5 N19SK10 N…

Issue 2, Nov 14
TRS Advanced Maintenance
11
Objective 5: CAN system refresh
Locate all CAN nodes on the machine, including Node 19.
M36 Machine
Control Enclosure
NextMove ES
(i/O Node 1)
Rising Table
Motor
(Servo Node 6)
Paste Dispense
Motor
(Stepper Node 10)
Machine I/O
(I/O Node 2)
Print Carriage
Motor
(Servo Node 7)
Print Carriage I/O
(I/O Node 3)
TRS I/O
(I/O Node 19)
USC I/O
(I/O Node 4)
CAN Terminator

TRS Advanced Maintenance
12
Issue 2, Nov 14
Objective 6: Identify Node 19 board and explain its function.
Use the TRS electrical drawing to complete the box below
Connector Function
N19PL1
N19PL2
N19PL3
N19SK5
N19SK10
N19SK16
N19SK18
Notes:
N19PL2
NSK819 1
NSK19 8 N SK119 4 N SK119 0
NSK519 1 N SK19 7
NSK19 4 N SK119 9N19SK11
N19SK5N19SK6N19PL3 N SK119 7
NODE C19 ONTROLLER
215023 ISSUE
N19SK16
NSK19 9NSK19 13N19PL1
N19SK12

Issue 2, Nov 14
TRS Advanced Maintenance
13
Objective 7: Locate, identify and test all TRS sensors and switches.
Use the TRS Option manual to identify sensor and switch types used on the TRS system.
Answer the following questions:
Which switch / sensor type is used for the following axis:
Rail At Tooling ___________________________________________
TRP Present ____________________________________________
TRP Home______________________________________________
Active Surround Present ___________________________________
TRP Over Rails __________________________________________
Z-lock Off _______________________________________________
Rail Width Home _________________________________________
Vacuum Leak Detector ____________________________________
Board at Stop____________________________________________
Board Stop in Position_____________________________________
Locate all the above switches / sensors on the machine.
Measure the supply voltage and sensor output voltage (flag in / flagout) for the Rail Width
Home sensor and Z-lock activated reed switch.
Find the sensors input and output positions in Diagnostics.
NOTES: