00194888-01_DE_EN - 第82页

Installation Manual, Station Software Version 603.01 Issue 11/2006 4 Inst allation Manual 4.1 Inst allation sequence See section 4.2.1 20 of 62 See section 4.2.1 See section 4.3.1 See section 4.10.3 See section 4.10.4 Se…

100%1 / 124
Installation Manual, Station Software Version 603.01 Issue 11/2006
3.4 Network configuration
Station computer
Machine controller
10Base-T
100Base-T
Private network between
station computer,
Vision computer (optional)
and machine controller
SIPLACE LAN
SIPLACE Pro
Twisted Pair TP
(100 MB)
Twisted Pair TP
(10 MB)
Vision computer
(optional)
100Base-T
Fig. 3-4: Network connections between the machine and SIPLACE Pro
A separate private network (100 Mbit) is set up between the station computer (and optionally the Vision
computer) and the machine controller via a subnet mask.
Fixed IP addresses for the station computer, Vision computer and machine controller can thus be assigned
for all SIPLACE machines. These IP addresses are not known outside the private network, for instance in
the SIPLACE LAN or customer LAN.
These IP addresses need not be further configured by the operator while the station software is being
installed.
IP address, station computer 192.168.255.249
IP address, machine controller 192.168.255.250
Vision computer IP Address 192.168.255.251
Subnet mask, station computer/machine controller 255.255.255.248
IP address range, SIPLACE LAN or
IP address range, customer LAN
172.22.xxx.xxx
is configured on-site
Subnet mask for SIPLACE-LAN or
subnet mask for customer LAN
255.255.0.0
is configured on-site
Table 3-10: Network configuration
19 of 62
Installation Manual, Station Software Version 603.01 Issue 11/2006
4 Installation Manual
4.1 Installation sequence
See section
4.2.1
20 of 62
See section
4.2.1
See section
4.3.1
See section
4.10.3
See section
4.10.4
See separate manual for details on installing the Windows XP
operating system (item no. 00194575-02)
4.4.3
For details on calibrating the touchscreen, see sections
and
4.4.4.
See separate manual for details on installing the Windows XP
Embedded operating system (item no. 00195327-01)
4.4 and 4.5
See sections
Installation Manual, Station Software Version 603.01 Issue 11/2006
4.2 Automatic BIOS settings on the station computer
A setup CD must first be created to automatically make the BIOS settings on the station computer. To do
this, you require a computer running Windows XP that is fitted with a DVD and CD-RW drive.
The image files necessary for creating the CD (see
Table 4-1) are in the "BIOS-Images" folder of the DVD
for version 603.01 of the software.
Station computer / computer type BIOS settings / ISO image
SMP16-CPU086 CPU086_SR_BIOS_Settings.iso
SIMATIC Box PC 627 CPU627_SR_BIOS_Settings.iso
Table 4-1: Files required for creating the Setup CDs for making the BIOS settings on the station computer
4.2.1 Creating a setup CD and making the BIOS settings on the station computer
Insert an empty writable CD in the CD-RW drive on any computer equipped with a CD RW drive.
Insert the DVD for version 603.01 of the software in the DVD drive.
In the Windows Explorer, open the "BIOS-Images" folder on the DVD.
Table 4-1
Open the image file for the relevant computer type (see
) using the installed CD writing
program and follow the instructions on screen.
Once the CD has been written, remove the CD and DVD from the drives.
Making the BIOS settings on the station computer:
Note:
Before you start work, ensure that the CD-ROM drive is set as the first boot device in the
BIOS to allow the computer to be booted from CD.
Insert the CD you have created in the external DVD drive on the station computer and boot from the
CD by switching the machine on. The BIOS settings are now performed automatically.
After the settings have been made, remove the CD from the drive and switch the machine off again.
21 of 62