8. Operation
8.1 "Opn. Mode" Tab Sheet
This tab sheet enables the operator to specify the operation mode for
the ACV system.
To use the ACV function, it is required to specify "Enable" for the ACV
function.
• Sheet Layout
When the "Opn. Mode" tab is pressed in the "OPN. MODE" window
(submenu), the corresponding tab sheet appears. Press the [Next]
button. The following tab sheet appears.
Fig. 3
*1 "ACV Function" Group Box
[Enable] Button
The ACV function becomes available.
[Disable] Button
The ACV function becomes unavailable.
When "Enable" is set for the ACV function and the ACV
checking is started, "ACV Check Mode" appears in the "Op-
erator Message" pane of the "AUTO OPN." window.
8. Operation
*2
*1
Note
0310-001 10 AIP01EGP

Fig. 4
*2 "Alarm for Component Remainder" Group Box
An alarm for component remainder can be issued according to the
component remainder data which is read for each feeder.
The alarm message "Alarm for Component Remainder" appears in
the "Operator Message" pane and the feeder No. related to the alarm
can be checked in the "ACV Check Status" tab sheet.
[Comp Remainder] Button
When the value under "Comp Rem" becomes smaller than the
specified one in the "ACV Check Status" tab sheet, an alarm for
component remainder is issued.
[P.C.B. Remainder] Button
When the value under "PCB Rem" (the estimated number of P.C.B.'s
which can be produced using the loaded components) becomes
smaller than the specified one in the "ACV Check Status" tab sheet,
an alarm for P.C.B. remainder is issued.
[Comp Feed Rem Tm] Button
When the value under "Feed Rem Tm" (the period of time during
which the loaded components can be supplied, that is, the time in
which the components are used up) becomes smaller than the speci-
fied one in the "ACV Check Status" tab sheet, an alarm for remain-
ing feed time is issued.
The time to be specified must be expressed in minutes.
As the time is calculated based on the time required to finish one
P.C.B., it may differ from the time in which all components are actu-
ally used up.
0310-001 11
AIP01EGP
8.1 "Opn. Mode" Tab Sheet
ACV Check Mode

[Disable] Button
No alarm for component remainder is issued.
Data Input Range
0 to 9999
Depending on the option selected in the "Alarm for Component Re-
mainder" group box, each value represents number of components,
number of P.C.B.'s, or time (minutes).
When "Enable" is set for the ACV function, the alarm func-
tion for the component remainder becomes available.
Note