SOM-1732-001.pdf - 第5页
1. Scope This feature is one of the specially designed features of ACV system. The component data can be communicated with the feeders special for ACV system by attaching the antenna for tag memory to the main ma- chine …

0310-001 3 AIP01EGP
Contents
Page
Before Use ................................................................................................ 1
Contents .................................................................................................... 3
1. Scope ..................................................................................................... 4
2. Function ................................................................................................ 4
3. Specifications ....................................................................................... 5
4. ACV System Configuration .................................................................. 6
5. ACV System .......................................................................................... 7
6. Tape Feeders ......................................................................................... 8
7. Scope of Actions .................................................................................. 9
8. Operation............................................................................................... 10
8.1 "Opn. Mode" Tab Sheet ................................................................. 10
8.2 "ACV Set" Tab Sheet ...................................................................... 13
8.3 "ACV Check Status" Tab Sheet .................................................... 15
9. Supplement ........................................................................................... 19
9.1 Details of ACV Antenna Section.................................................... 19
9.1.1 Details of Antenna Section (TCM-X100/-X200/-X300) ........... 19
9.1.2 Details of Antenna Section (TCM-X110/-X210/-X300) ........... 20
9.2 Parts Location ................................................................................. 21
9.2.1 Layout of ID Controller (TCM-X100/-X200/-X300) .................. 21
9.2.2 Head Section in Main Machine Section 2
(TCM-X110/-X210/-X300) ..................................................... 22
9.2.3 Layout of Control Board
(TCM-X100/-X200/-X300, TCM-X110/-X210/-X300) ............ 23
9.3 Electrical Circuit Diagram .............................................................. 24
9.3.1 Integrated Block Connection Diagram
(TCM-X100/-X200/-X300) ..................................................... 24
9.3.2 Integrated Block Connection Diagram
(TCM-X110/-X210/-X300) ..................................................... 25
9.3.3 ID Controller Connection Diagram
(TCM-X100/-X200/-X300, TCM-X110/-X210/-X300) ............ 26
9.4 Cord Connection Diagram ............................................................. 27
9.4.1 Cable Connection Diagram
(TCM-X100/-X200/-X300, TCM-X110/-X210/-X300) ........... 27

1. Scope
This feature is one of the specially designed features of ACV system.
The component data can be communicated with the feeders special for
ACV system by attaching the antenna for tag memory to the main ma-
chine of TCM-X series. Also, the feeder component data can be man-
aged by reading the barcode labels affixed on the reels for components
and tape feeders.
2. Function
• Check Function for Wrong Installation of Feeders
When the automatic operation is started, this function works to check
if all feeders and components are correctly allocated so as to prevent
any wrong installation of feeders.
• Component Remainder Management
The component supply time can be presumed by managing the num-
ber of remaining components at real time for each feeder.
(Alarm for Component Remainder)
• Tape Feeder Management Function
(Offset Management, Pick-up Error Data Management)
This function provides record/management of offset values to cor-
rect the deviation when the feeder is set, and record/management of
the pick-up errors.
1. Scope
0310-001 4 AIP01EGP

3. Specifications
Table 1
1. Device • Application for ACV System (Main Machine)
Configuration • Tape Feeder with Tag Memory
• Dual Tape Feeder with Tag Memory
• Bulk Feeder with Tag Memory
2. Applicable Feeders Specially for ACV System Feeders
• Tape Feeders with Tag Memory
• Dual Tape Feeders with Tag Memory
• Bulk Feeders with Tag Memory
Notes : (a) The feeders called "Specially for ACV System Feeders"
are equipped with Tag memory where data such as the
component IDs and the number of component are written.
(b) The feeders for special specified "Application for SIF Sys-
tem" cannot be used.
3. Tag Memory Memory Capacity : 128 Bytes
Memory Type : FeRAM
Memory Life : 1 billion access times
(No. of access times is total of reading and
writing times)
Data Preservation Time : 10 years
(After the access for writing or reading)
3. Specifications
0310-001 5 AIP01EGP