Adjus t ment In str uc tio ns SI PLA CE HS- 50 6 Gantries Edition 12/00 6.1 Track Signals 101 3URFHGXUH Å T urn on t he m achi ne. Å Relate yo ur meas urement s etup to the x-, or y- axis respe ctively . (Se e fi…

6 Gantries Adjustment Instructions SIPLACE HS-50
6.1 Track Signals Edition 12/00
100
$QDORJ7UDFN6LJQDOV*DQWU\$[HV
0HDVXUHPHQW6HWXSRI$QDORJ7UDFN6LJQDOV
2VFLOORVFRSH6HWWLQJV
Inkrementalgeber X- / Y- Achse /
incremental encoder x- / y- axis
SIPLACE HS-50
Auflösung des Maßstabes: 1 Digit = 1 m
measuring scale: 1 dgt = 1 m
µ
µ
Spursignal - Tester /
track signal tester
BNC - Leitung
BNC line
track
zero pulse
analog
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH 1
track A of
track signal
tester
DC 0.5 V/ DIV
x- / y- mode
auto 5 ms/ DIV
CH 2
track B of
track signal
tester
DC 0.5 V/ DIV
x- / y- mode

Adjustment Instructions SIPLACE HS-50 6 Gantries
Edition 12/00 6.1 Track Signals
101
3URFHGXUH
Å Turn on the machine.
Å Relate your measurement setup to the x-, or y- axis respectively. (See fig 6.5 - 3).
Å Adjust the oscilloscope.
Å Set the track signal tester to the "Oscilloscope cal" position.
Å With the help of the positioning switches CH1 and CH2, move the light spot exactly to the
center of the crosshairs of the screen.
Å Set the track signal tester to the "signal output" position.
Å Manually, move the appropriate axis (x = head / y = gantry) back and forth.
– If you adjusted the read head correctly, the following illustration will appear on the screen of
the oscilloscope:
$QDORJH=HUR3XOVHRIWKH*DQWU\$[HV
NOTE
The pulse width of the analog zero pulse is dependent on the speed at which the axis is
traversed.

6 Gantries Adjustment Instructions SIPLACE HS-50
6.1 Track Signals Edition 12/00
102
0HDVXULQJ6HTXHQFH
Å Turn the main switch to "ON".
Å Connect the track signal tester to the incremental encoder 1 of the x- / y- axis.
(See
fig 6.1 - 1).
NOTE
The testing sequences of the x- and y- axes are identical.
2VFLOORVFRSH6HWWLQJV
Å Connect the oscilloscope to the track signal tester.
Å Set the oscilloscope to the values of the table below.
&DOLEUDWLRQRI2VFLOORVFRSH
Å Set the track signal tester to selector switch "Oscilloscope cal.".
Å With the help of the positioning switch of CH 1, set the direct current signal on the center of the
upper half of the screen.
0HDVXULQJWKH=HUR3XOVH
Å Set the oscilloscope to the value of the table below:
Å Set the track signal tester to position "Signal output".
Å Manually, move the appropriate axis (x = head / y = gantry) back and forth.
&KDQQHO 6LJQDO &RXSOLQJ <'HIHOFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH 1
"Oscilloscope
cal."
zero pulse DC 0.5 V/ DIV auto 20 ms
&KDQQHO 6LJQDO &RXSOLQJ <'HIOHFWLRQ 7ULJJHU ;'HIOHFWLRQ
CH 1
signal output zero pulse DC 0.5 V/ DIV
2.5V norm
pre- trig. 50%
20 ms