2 Operational Safety Adjust men t Ins tru ct ion s SIPL ACE H S-50 2.5 Energy Level after Switching Off Main Switch Edition 12/00 48  .(<  (1) Main sw itch (2) Cont rol u nit (3) Power s upply uni t ± 12 VD C (4) Po…

100%1 / 186
Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 12/00 2.5 Energy Level after Switching Off Main Switch
47
.(<
(1) Main switch
(2) Service socket behind protective door
(3) Compressed air unit
(4) Servo unit
(5) Measuring unit in servo unit
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.5 Energy Level after Switching Off Main Switch Edition 12/00
48
.(<
(1) Main switch
(2) Control unit
(3) Power supply unit ± 12 VDC
(4) Power supply unit ± 15 VDC
(5) Power supply unit + 5 VDC/+ 24 VDC
(6) Power supply unit + 5 VDC/+ 50 VDC
Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 12/00 2.5 Energy Level after Switching Off Main Switch
49
 3ODFHPHQW6\VWHP6ZLWFKHG2IIDWWKH0DLQ6ZLWFKEXW6WLOO&RQQHFWHG
The following table specifies the voltages of modules when the placement system is switched off
at the main switch, but still remains connected to the mains supply.
DANGER
The following components still carry potentially lethal voltages even if the main switch is switched
off:
Cable connection terminals 1, 3, and 5 of S1 main switch,
Z1 mains filter,
BU1 service socket,
F1 automatic circuit breaker for the service socket.
The color of all single wires, which still carry potentially lethal voltages even if the main switch
is switched off is brown.
0RGXOH 9ROWDJH
Mains filter Z1
Terminals L1, L2, L3
3 x 204 V AC
3 x 230 V AC
3 x 380 V AC
3 x 400 V AC
3 x 415 V AC
Service socket BU1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC
Circuit breaker F1
115 V AC
130 V AC
220 V AC
230 V AC
240 V AC