Adjustment Instructions SIPLACE HS-50 4 Overview Voltages
Edition 12/00 4.2 Power Supply Unit
71
 9ROWDJHVRIWKH3RZHU6XSSO\8QLW
Switching on the main switch, the following voltages will be generated and switched or not
switched to the modules:
9ROWDJH 0RGXOH
200 VDC servo unit unswitched
100 VDC servo unit unswitched
6 VDC servo unit switched
30 VDC servo unit switched
50 VDC servo unit switched
38 VDC component tables PCB handling switched
8 VDC component tables switched
3 x 230 VAC lifting motors unswitched
230 VAC station computer and PC switched
230 o.115 o. 265 VAC service socket independent from main switch
4 Overview Voltages Adjustment Instructions SIPLACE HS-50
4.3 Control Unit Edition 12/00
72
 &RQWURO8QLW
Switching on the main switch , the DC / DC - converter in the control unit will be supplied with 50
VDC from the power supply unit. The following voltages will be generated in the control unit:
+ 5 VDC supplying the digital electronic.
± 12 VDC supplying the digital electronic.
± 15 VDC supplying the analog electronic.
+ 24 VDC supplying the control circuits, relay etc.
The measuring points are found in the detailed circuit diagram "Control unit HS-50, front view, in
chapter 3.
Adjustment Instructions SIPLACE HS-50 4 Overview Voltages
Edition 12/00 4.4 Main Distributor
73
 0DLQ'LVWULEXWRU
Switching on the placement system you can measure the following voltages on the terminal strip
of the main distributor: (See detailed circuit diagram "Main distributor in chapter 3"):
5HJXODWHG9ROWDJHV
5 VDC, ± 12 VDC, ± 15 VDC, 24 VDC
8QVDWXUDWHG9ROWDJHV
8 VDC, 38 VDC, 50 VDC