4 Overview Voltages Adjustment Instructions SIPLACE HS-50
4.6 Measuring Voltages of the Power Supply Unit Edition 12/00
78
246
135
F3
135
246
SZ1
K14
K12
K11
135
246
MS1A
MS1
S1
MS5 MS6MS4MS3
135
2 64 2 64
1 53 31 5
42 6 624
5
13
F4
426
3
1
5
F10F9F8F7F6F5
111111
222 222
F1
2
1
SZ2 SZ3
SZ23
246
1351
3
5
2
4
6
2
4
6
1
3
5
K232
K234
K34
K33
K32
K31
K21
K22
K23
K24
SSK
1 375
4268
A1+
A2-
SZ4
X1
VUWW
PE
PE
N
BU1
M8
F11
2
1
54 6614 24 4434X4 X6L-
13L+ X3X1 X5 533323 43 65
Netz
Power
Channel 1
Kanal 1
Channel 2
Kanal 2
Adjustment Instructions SIPLACE HS-50 4 Overview Voltages
Edition 12/00 4.6 Measuring Voltages of the Power Supply Unit
79
0RGXOH 'HVLJQDWLRQ &ODPSV 9ROWDJHV
X1
connecting terminal panel
power supply
U, V, W
3 x 204 VAC / 3 x 380 VAC /
3 x 400 VAC / 3 x 415 VAC
BU1
service socket 115 VAC / 220 VAC / 230VAC / 240 VAC
S1
main switch
1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC /
3 x 400 VAC / 3 x 415 VAC
MS1
motor protective switch
1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC /
3 x 400 VAC / 3 x 415 VAC
SZ1
main contactor
1, 3, 5 u.
2, 4, 6
3 x 204 VAC / 3 x 380 VAC
3 x 400 VAC / 3 x 415 VAC
MS3
MS4
MS5
MS6
motor protective switch
PCB conveyor 1
motor protective switch
PCB conveyor 2 (option)
1, 3, 5 u.
2, 4, 6
1, 3, 5 u.
2, 4, 6
3 x 230 VAC
3 x 230 VAC
3 x 230 VAC
3 x 230 VAC
SZ2
contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ3
contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ23
contactor
1, 3, 5
2, 4, 6
3 x 140 VAC
3 x 140 VAC
SZ4
contactor
A1 (+) - A2 (-)
1, 2
3, 4
5, 6
24 VDC
24 VDC against ground
24 VDC against ground
24 VDC against ground
SSK
protective contactor
combination
L+, X3, X5 24 VDC against ground
F1
fuse
service socket
1, 2
115 VAC / 220 VAC
230 VAC / 240 VAC
against N on the connecting terminal panel 1
F3
fuse
board net
1, 3, 5
2, 4, 6
3 x 230 VAC
F4
fuse
x- / y- axis
1, 3, 5
2, 4, 6
3 x 140 VAC
F5
fuse
star - axis
1, 2 100 VDC against minus of rectifier V3.
F6
fuse
z- and dp - axis
1, 2 30 VDC against minus of rectifier of V4.
4 Overview Voltages Adjustment Instructions SIPLACE HS-50
4.6 Measuring Voltages of the Power Supply Unit Edition 12/00
80
 0HDVXULQJ9ROWDJHVRQ5HFWLILHUV9WR9
The graphic below displays the position of rectifiers V1 to V7 as well as their pin configurations.
Å In order to measure the voltages of rectifiers V1 and V7, you must first remove the the
protective plexiglass pane.
DANGER! RISK OF LIFE THROUGH ELECTROCUTION
Å Use the main switch to turn off the system.
Å Disengage the system from the power supply.
Å Wait approximately 1 min, until the residual voltages have decreased to a harmless value.
(Electrolytic capacitor C1).
Å Untighten both M5 - cap screws of rectifiers V1 and V7.
Å Remove the protective plexiglass pane.
Å Turn on the system and start it.
Å Measure the voltages.
NOTE
The system must have been started first, otherwise there will be no voltage on the rectifier V1
(3 x 140 VAC). V1 generates the supply voltage of 200 VDC from the 3 x 140 VAC for the servo
amplifier gantry axes and 100 VDC for the servo amplifier of the star - axes.
These 100 VDC and 6 VDC are fed to the alternating voltage inputs of rectifier V2 .
Rectifier V2 serves to keep the switch between 6 VDC and 100 VDC free of interrupts.
Before the start of the system, there are only 6 VDC on the rectifier V1.
F7
fuse
component table (feeder)
1, 2
38 VDC against minus of rectifier V5.
(See fig 4.6 - 2).
F8
fuse
PCB conveyor
1, 2
38 VDC against minus of rectifier V5.
(See fig 4.6 - 2)
F9
fuse
component table (logic)
1, 2
8 VDC against minus of rectifier V6.
(See fig 4.6 - 2)
F10
fuse
control unit
1, 2
52 VDC against minus of rectifier V7.
(See fig 4.6 - 2)
F11
fuse
in rush limiter
1, 2
30 VDC against minus of rectifier V8.
(See fig 4.6 - 2).