00198243-01_AI_BulkFeederX_XS-SX_DE EN - 第125页
4 Retrofit kit for X-Series S 4.5 Connecting the BulkFeeder X computer to the station computer Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 125 ► Run the…

4 Retrofit kit for X-Series S
4.5 Connecting the BulkFeeder X computer to the station computer
124 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017
4.5 Connecting the BulkFeeder X computer to the station
computer
4.5.1 Removing the station computer
To prepare the station computer for connection of the BulkFeeder X computer, you need to remove
the station computer. To do so, proceed as follows:
► Unplug all press-fit connections to the station
computer. Mark their positions, to make clear as-
signment easier later on.
NOTICE!
For machines with serial number > H001: the
connection (1) should be empty so that the
BulkFeeder X computer can be connected
there later. If the connection is occupied, you
will need to fit an additional LAN card in the
station computer.
.
► The station computer is fitted using velcro! Re-
move the station computer.
4.5.2 Inserting the cable for the power supply and LAN connection to the
BulkFeeder X computer
The cable for the power supply and the LAN connection must be inserted into the machine. To do
so, proceed as follows:
► Run the power supply cable (1) and the LAN
cable (2) via the empty installation place, from
the station computer, through the opening in the
bottom of the machine.

4 Retrofit kit for X-Series S
4.5 Connecting the BulkFeeder X computer to the station computer
Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 125
► Run the cable through the bottom of the machine
in placement area 1 to location 4.
► Run the cable out of the bottom of the machine
from location 4 to the side cover.
► Then run the cable behind the side cover from
location 4.

4 Retrofit kit for X-Series S
4.5 Connecting the BulkFeeder X computer to the station computer
126 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017
4.5.3 Connecting the cable to the BulkFeeder X computer
► Connect the cable for the power supply (1) and
the grounding (2).
► Connect the LAN cable (3).
4.5.4 Fitting the station computer
► Reposition the station computer on the velcro.
Pay attention to the position of the cable.