00198243-01_AI_BulkFeederX_XS-SX_DE EN - 第88页

1 Introduction 1.4 Staff Qualifications and Training 88 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 1.3.3.5 Dispatching ESD Modules ► Always store modul…

100%1 / 148
1 Introduction
1.3 Other Instructions
Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 87
1.3.2 Use of Original SIPLACE Accessories and Spare Parts
Only use original spare parts and authorized accessories. The use of other parts will affect safety
and will invalidate the liability for any consequential damage.
1.3.3 ESD Guidelines
1.3.3.1 Definition of ESD
Almost all of the modules in use today are equipped with highly integrated MOS blocks and com-
ponents. The manufacturing techniques used mean that these electronic components are ex-
tremely sensitive to overvoltage and thus to electrostatic discharge.
Fig.6: ESD label
The abbreviation for such modules is "ESD"(Electrostatic Sensitive
Device). This is used internationally, although the German abbreviation
"EGB" may also be seen. The following symbol on cabinet rating plates,
racks or packaging indicates that components which are sensitive to elec-
trostatic discharge have been used and thus that the modules concerned
are also touch-sensitive.
ESDs can be destroyed by voltages and electrostatic charges that are far below the level that can
be perceived by humans. Such voltages occur if a person touches a component or module
without earthing themselves. Components that are exposed to such overvoltage do not generally
appear to be defective immediately - incorrect behavior starts after the component or module has
been in operation for some time.
1.3.3.2 Important Measures to Protect Against Static Charging
Most plastics can easily become charged and must therefore be kept away from at-risk com-
ponents.
Always ensure that people, the workplace and packaging are safely earthed when handling
electrostatic sensitive components.
1.3.3.3 Handling ESD Modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other
work. If it is necessary, make sure that you do not touch the pins or printed conductors when you
pick up flat modules.
Do not touch components unless
You are constantly earthed by an ESD wrist strap or
You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a con-
ductive and earthed object immediately before you touch the module (such as unpainted parts of a
switch cabinet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g.
plastic films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD
foam, ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10cm
away from the screen.
1.3.3.4 Measurements and Modifications to ESD Modules
Measurements of the assemblies may only be taken if
The measuring device has been grounded (e.g. via protective conductor) or
you discharge the measuring head before taking measurements with a potential-free measur-
ing device (e.g. by touching an unpainted metal part of the controller casing).
Always use an earthed soldering iron if you carry out any soldering work.
1 Introduction
1.4 Staff Qualifications and Training
88 Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017
1.3.3.5 Dispatching ESD Modules
Always store modules and components in conductive packaging (e.g. metalized plastic bags
or metal sleeves) and dispatch them in conductive packaging.
If the packaging is not conductive, place the modules in a conductive envelope before pack-
aging. Use conductive expanded rubber, ESD bags, domestic aluminum foil or paper, for ex-
ample.
If the module has integral batteries, ensure that the conductive packaging does not touch or
short-circuit the battery terminals and, if necessary, first cover the terminals with insulating
tape or material.
1.3.4 Release History
Document
SIPLACE SX series
SIPLACE X-Series S
Assembly Instructions
Edition Changes
07/2017 First edition
Assembly instructions for retrofitting an SIPLACE SX-Series or SIPLACE X-
Series S for operation with a BulkFeeder X.
1.4 Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and maintenance of the machine and the add-on devices and are suitably qualified, e.g.:
Have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
Have been trained or instructed in the upkeep and use of appropriate safety equipment in
accordance with normal safety standards.
Have received first aid training.
2 Brief description
2.1 Restrictions
Assembly Instructions / Montageanleitung SIPLACE BulkFeeder X Retrofit Kit for SX Series and X Series S 07/2017 89
2 Brief description
A machine-specific retrofit kit is required for putting BulkFeeder X devices into operation.
These retrofit kits can be ordered by quoting the following material numbers:
Retrofit kit BulkFeeder X for the SX-Series machine [00141660-xx]
Retrofit kit BulkFeeder X for the X-Series S machine [00141650-xx]
2.1 Restrictions
Restrictions for operating the BulkFeeder X are described in the BulkFeeder X user manual
[00198045-xx].
SX-Series
A maximum of two BulkFeeder X devices can be connected to the machine. This equates to one
BulkFeeder X per location.
X-Series S
A maximum of four BulkFeeder X devices can be connected to the machine. This equates to one
BulkFeeder X per location.
2.2 Tools and equipment required
The following tools and equipment are required for the work described in this manual:
Standard tools
Cable ties
Allen key, size 4, chrome-plated [03160943-xx]
Documents
Quant-
ity
Designation Item no.
1 BulkFeeder X - operating manual 00198045-xx
1 Retrofit kit for SX-Series and X-Series S - assembly instruc-
tions
00198243-xx