Vakuum Tooling AMKOR X4 OS Applikation - 第50页
Installation instructions Vacuum Tooling AM KOR (001885 01-01) SIPLACE X4 / OS Application 03/2006 Edition 50 Programming the s ensor: 2 2

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
49
2.8.3 Connecting and programming the vacuum sensor
2
2
2
Important: the vacuum measuring hose (PUN6) is fitted at the 1/8“ connection. The connection for
PUN 3 is simply a vent plug. 2
2
Recommended settimgs for the existing customer PCB: 2
2
Connection between vacuum hose and vacuum measurement
Electrical connection for vacuum sensor
Vent plug
OUT1
OUT2
HYS, N.O.
HYS, N.C.
H1 = 600 mbar
A2 = 150 mbar
h1 = 0,05 mbar
b2 = 0,05 mbar

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
50
Programming the sensor: 2
2

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
51
2.9 Deliverables
– Vacuum tooling activation circuit with vacuum suction device for placement area 1
– Vacuum tooling activation circuit with vacuum suction device for placement area 2
– Vacuum plate for customer board
– Maintenance unit with mounting plate
– Modified cover for conversion board
– Retrofit instructions
Special design Vacuum Tooling AMKOR (00188501-01) (item no.: 00195043-01).
2.10 Possible error messages and troubleshooting
2
Fig. 2.10 - 1 Error message for lack of compressed air
Troubleshooting 2
– Check the compressed air connections
– Check the set pressure on the maintenance unit.