Vakuum Tooling AMKOR X4 OS Applikation - 第52页

Installation instructions Vacuum Tooling AM KOR (001885 01-01) SIPLACE X4 / OS Application 03/2006 Edition 52 2 Fig. 2.10 - 2 V acuum built up in placement area 1 is too low T roubleshooting 2 – Check whether all the vac…

100%1 / 56
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
51
2.9 Deliverables
Vacuum tooling activation circuit with vacuum suction device for placement area 1
Vacuum tooling activation circuit with vacuum suction device for placement area 2
Vacuum plate for customer board
Maintenance unit with mounting plate
Modified cover for conversion board
Retrofit instructions
Special design Vacuum Tooling AMKOR (00188501-01) (item no.: 00195043-01).
2.10 Possible error messages and troubleshooting
2
Fig. 2.10 - 1 Error message for lack of compressed air
Troubleshooting 2
Check the compressed air connections
Check the set pressure on the maintenance unit.
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
52
2
Fig. 2.10 - 2 Vacuum built up in placement area 1 is too low
Troubleshooting 2
Check whether all the vacuum holes are covered (the as-delivered setting allows placement
with just one vacuum hole open)
Check whether there are any components or dirt on the vacuum plate.
Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
53
2
Fig. 2.10 - 3 The vacuum cannot be fully dissipated after the placement process.
Troubleshooting 2
Check the vacuum tooling connections