Vakuum Tooling AMKOR X4 OS Applikation - 第53页
Installation instructions Vacuum Tooling AM KOR (00188501-01) SIPLACE X4 / OS Application 03/2006 Edition 53 2 Fig. 2.10 - 3 The vacuum cannot be fully dissipated after the placement process. T roubleshooting 2 – Check t…

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
52
2
Fig. 2.10 - 2 Vacuum built up in placement area 1 is too low
Troubleshooting 2
– Check whether all the vacuum holes are covered (the as-delivered setting allows placement
with just one vacuum hole open)
– Check whether there are any components or dirt on the vacuum plate.

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
53
2
Fig. 2.10 - 3 The vacuum cannot be fully dissipated after the placement process.
Troubleshooting 2
– Check the vacuum tooling connections

Installation instructions Vacuum Tooling AMKOR (00188501-01) SIPLACE X4 / OS Application
03/2006 Edition
54
2
Fig. 2.10 - 4 Attention: The automatic width adjustment must be deactivated.
If the conveyor is moved manually, then this error message appears. The conveyor moves, even
though the vacuum tooling is fitted. 2
2
Risk of crashing. 2
2
2
2.11 Refitting the standard conveyor
– Connectors X34/X35 should be removed so that the special design is no longer present for the
machine and the software works in standard mode.
– Detach the hoses and remove the base plate from the lifting table together with the vacuum
elements.
– Disconnect the air supply to the maintenance unit.
2