00195447_EN_DE_Install_SR604 - 第8页

Installation Manual, Station Software Version 604.01 Issue 04/2007 3 Upgrade to the 604.xx sof tware version When upgrading to the 604.xx software vers ion, please consider following: - Fix the temperature warning labels…

100%1 / 96
Installation Manual, Station Software Version 604.01 Issue 04/2007
7 of 48
2.2 Hardware components
Station computer
MC computer (machine controller)
Vision computer (optional, required for the 3D coplanarity sensor option)
2.3 Languages
User interface for station computer and SIPLACE Vision:
The standard package contains German and English versions. Other languages contained in the
languages package are optional and available under item number 00385490-01.
The following table indicates which languages are available for the station software and SIPLACE Vision:
Language Station software /
SIPLACE Vision
French x
Italian x
Spanish (Mexico) x
Portuguese (Brazil) x
Hungarian x
Czech x
Polish x
Russian x
Estonian x
Chinese (simplified) x
Chinese (traditional) x
Korean x
Japanese x
Thai *) x
*) Only available for GUIs (English online help)
SITEST user interface:
German and English are included on the software CD.
Installation Manual, Station Software Version 604.01 Issue 04/2007
3 Upgrade to the 604.xx software version
When upgrading to the 604.xx software version, please consider following:
- Fix the temperature warning labels (03031926-01) at the C&P20 head (see the figure).
- After an upgrade to the 604.xx software version, calibrate the heads of the D1, D2 and D4 machines.
The temperature compensation is activated for these machines.
- After installing the 604 software version, please update the X feeder eSW version.
8 of 48
Installation Manual, Station Software Version 604.01 Issue 04/2007
3.1 Upgrade packages and components for upgrading from Version 603.x
Caution:
For upgrading to the software version 604.x on the SIMATIC BoxPC 627, please consider the
installation manual “Windows Embedded XP operating system for the MC German and
English” (00195327-xx). The standard media package (03054699-xx) is required.
It is not necessary to install the Windows embedded XP operating system for the other
machines.
No further upgrade packages or components are required.
3.2 Upgrade packages and components for upgrading from Version 601.x
or 602.x
Caution:
For upgrading to the software version 604.x, please consider the installation manual “Windows
Embedded XP operating system for the MC German and English” (00195327-xx).
The standard media package (03054699-xx) is required.
The following upgrade packages for SIPLACE X4, X2 and X3 machines with CPU 076 are required:
- Upgrade package for SIPLACE X4 with CPU 076 Æ Computer upgrade to CPU 086
Item number: 03029123S03
- Upgrade package for SIPLACE X2 and X3 with CPU 076 Æ 128 MB memory expansion
Item number: 03051831