YG100R_Ope_E - 第113页
Appendix Appendix Contents A 1 . S p e c i f i c a t i o n s A - 1

3-21
3
Starting and ending production
3.10 Coplanarity checker (YG100R and YG88R only)
Monitor: Co-PlaCheck (Coplanarity Check)
24316-M0-00
• Head No.
Displays the head number currently being used.
• Parts No.
Displays the part number currently being used.
• Parts Name
Displays the part name currently being used.
• Co-pla. Threshold [μm]
Displays the coplanarity tolerance that was set in parts information.
• Error Number
Displays coplanarity error numbers.
• Pass Count
Displays the number of images that were captured during coplanarity check.
• Max. Co-planarity Pos.
Displays the lead number that was measured as the maximum coplanarity value.
• Min. Co-planarity Pos.
Displays the lead number that was measured as the minimum coplanarity value.
• Max-Min Co-planarity [μm]
Displays the coplanarity measurement result.
• Co-planarity Max. [μm]
Displays the maximum coplanarity value.
• Co-planarity Min. [μm]
Displays the minimum coplanarity value.
• Recognition Height
Displays the recognition height (height to underside of components).

A-1
Appendix
A1. Specifications
n
YG series specifications
Item
Specifications
YG88R YG100R YG200 (YG200L) YG300
Operating ambient temperature
Function guaranteed: 15 to 35°C
Accuracy guaranteed: 20 to 28°C
Operating ambient humidity 20 to 90% (no condensation), optimal range: 50 to 60%
Noise level 73.9dB 73.9dB 75.2dB 72.0dB
Power requirement 3-phase AC 200/208/220/240/380/416 V ± 10%, 50/60 Hz
Average power consumption
0.72 kW (main unit only)
0.90 kW (including dYTF)
0.96 kW (including sATS)
1.0kW (1.1kW) 2.6kW
Power cable (conductor cross-section
area)
3.5 mm
2
or more 6.0 mm
2
or more
Overvoltage category *
1
Category III
Pollution degree *
1
Degree 2
Supply air pressure *
2
0.55Mpa
350nl/min
0.55Mpa
400nl/min
0.55Mpa
500nl/min
Board transport height *
3
900 mm ± 10 mm
Data
Number of mounting points *
4
10,000 points
Number of part types 255 types per board
Number of fiducial marks *
5
128 sets per board
*1: Conforms to IEC60664-1.
*2: Clean, dry air passed through an air dryer and filter.
*3: Distance from the floor surface to the upper surface of conveyor belt.
*4: Decreases with the number of boards, blocks and fiducial marks.
*5: When using 2-point fiducial mode.
c
CAUTION
Conveyor's board sensors may fail to detect a production board if it has a slit or cutout.
n
NOTE
For more detailed information not listed above, please refer to specification sheets.