M3plus_OperationManual_e - 第34页
2 Basic oper ation 2 - 1 1. Before operation The following explains how to cancel emergency stop and clear errors. Read before operating the machine. 1.1 Canceling emergency stop Follow these steps to cancel emergency st…

2
Basic operation
2 -1
1. Before operation
The following explains how to cancel emergency stop and clear errors. Read before operating the
machine.
1.1 Canceling emergency stop
Follow these steps to cancel emergency stop.
1
Release the emergency stop button.
Turn the emergency stop button clockwise to release it.
2
Check safety.
Before continuing the procedure, check the surrounding area for safety.
3
Press the [READY] button.
Pressing the [READY] button on the operation panel turns on the servomotors.
Press the [READY] button to turn on the servo.
[READY] button
23103-5E-2A
4
Check the signal light and screen display.
Check that the red lamp of the signal light is off and the emergency stop sign on the
operation screen is now off.

2 -2
2
Basic operation
1.2 Clearing an error
If an error occurs a buzzer sounds and a yellow warning screen appears. To clear the
error, use the following steps.
1
Turn off the buzzer.
Press the [ERROR CLEAR] button on the operation panel or the [BUZZER OFF] button
on the error screen to turn off the buzzer.
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make
a note of the description.
3
Clear the error screen.
Press the [ERROR CLEAR] button on the operation panel again or the [ERROR CLEAR]
button on the error screen to clear the error screen.
4
Check the signal light and screen display.
Check that the yellow lamp of the signal light is off and the error message on the
upper left of the status area on the operation screen is now off.
1. Before operation