00192156-04 - 第10页

Maintenance Maintenance Instr uctions F 2 Everything you will need f or maintenance 03/2003 US E dition 10 2 2 2 2 2 2 2 2 2 2 2 2 2 V acuum ge nerator for Pick&Plac e head 00305378- 01 O-ring 6 x1 0032353 5-02 O-rin…

100%1 / 100
Maintenance Instructions F Maintenance
03/2003 US Edition 2 Everything you will need for maintenance
9
2.2 Consumables
Have the following consumables to hand before you start the maintenance:
2.3 Spare parts
Have the following spare parts to hand before you start the maintenance:
Consumables Article number
Protective latex gloves 00372972-01
Soft, lint-free cloths
Lint-free cottonwool buds 00352931-02
SIPLACE cleaning cloth 00315253-02
Lens cleaning tissue (e.g. Kodak)
Ethyl alcohol
ISOFLEX TOPAS, NCA 52 00328369-01 1 kg can,
00330850-01 50g tube
WD40, 400 ml 00325833-01
UNISILKON L250L 00310259-01
Z axis oil dispenser with Structovis GHD 00367071-01
Grease cartridge with Urethyn E/M2 02101696-01
Spare parts Article number
Pneumatic maintenance unit
F4 / F5 / F5HM
F3 / F4 Old
00357795-01
00315948-02
Filter G1/2 Modulair, 112 5µ
F4 / F5 / F5HM
F3 / F4 Old
00343010-01
00316488-01
Filter insert, 5 microm. for series 112
F4 / F5 / F5HM
F3 / F4 Old
00355386-01
00330406-01
Silencer for Collect & Place head 00320964-01
Maintenance Maintenance Instructions F
2 Everything you will need for maintenance 03/2003 US Edition
10
2
2
2
2
2
2
2
2
2
2
2
2
2
Vacuum generator for Pick&Place head 00305378-01
O-ring 6x1 00323535-02
O-ring for valve plunger 00345127-01
Viledon filter mat, 225 x 362 00304048-01
Set of cleaned ceramic nozzles or new nozzles
Set of clean sleeves
Set of clean valve plungers
Valve plunger 00330711-02 (12 x)
Z axis toothed belt 00334936-01
Distributor 00319827-02
O-ring, turning station 00320043-01
Toothed belt, turning station 00320041-01
Spare parts Article number
Maintenance Instructions F Maintenance
03/2003 US Edition 3 Important points to note when carrying out maintenance work
11
3 Important points to note when carrying out main-
tenance work
The maintenance intervals given for inspecting and replacing the filter elements are only valid for
the specified compressed air quality (compressed air specification). If other qualities are used,
the maintenance intervals should be shortened accordingly. 3
CAUTION
NEVER use compressed air to clean inside the placement machine’s modules. 3
Enter the completed maintenance work in the maintenance schedule. We recommend that you
carry out the tasks in the order given in the maintenance schedule. 3
3
3