Clean the X/Y scales 6
a Use a lint-free cloth dipped in ethyl alcohol to clean the incremental scales for the X and Y
axes.
6
Dirty scales can cause counting errors on the X and Y axes, and thus lead to incorrect or inaccu-
rate placing. 6
6
6
6
Change the nozzle changer magazines 6
: Use the "Single Functions" menu to return the nozzles of the Collect&Place head to the nozzle
changers.
s Remove the nozzle changer magazines and replace them with magazines with cleaned ce-
ramic nozzles or new nozzles.
: Use the Single Functions menu to pick up the nozzles of the Collect & Place head.
6
6
: Empty the nozzle reject bin.
: Repeat the job at the other location.