00192156-04 - 第49页
Maintenance Inst ructions F Maintenance 03/2003 US Edition 8 2-monthly maintenance work 49 : Remove the bla ck blanki ng cap by p ressing do wn on the yel low cap r elease (at the back) and turning the blank ing cap cou …

Maintenance Maintenance Instructions F
8 2-monthly maintenance work 03/2003 US Edition
48
8
Maintenance Instructions F Maintenance
03/2003 US Edition 8 2-monthly maintenance work
49
: Remove the black blanking cap by pressing down on the yellow cap release (at the back) and
turning the blanking cap counter-clockwise (bayonet fitting).
a Remove the condensate tank by pushing it up, turning it counter-clockwise and then pulling it
down (bayonet fitting).
s Unscrew the filter casing from the compressed air maintenance unit.
d Loosen the Phillips screw to remove the filter from the filter casing.
: Replace the filter if it is dirty.
: Reverse the order described above to fit the filter and filter casing.
8
: Then open the main compressed air valve again.
8
8
Inspect or replace the silencer on the Collect & Place head 8
f Check the silencer for the Collect & Place head for dirt.
If it is discolored, detach the retainer by turning it counter-clockwise.
g Replace the dirty silencer with a new one and reverse the order described above to fit.
8
8
8
8
8
8
8
8
8
8
8
8
8

Maintenance Maintenance Instructions F
8 2-monthly maintenance work 03/2003 US Edition
50
8