Sonic Buzzer für D4 - 第19页

SOKO 2 Assembly instruc tions SOKO Sonic Buzzer SIPLACE D4 10/2007 Edition 19 2 Assembly instructions SOKO Sonic Buzzer SIPLACE D4 2.1 Functionality / Features – When the SI PLACE encoun ters pick-up e rror an d the SIPL…

100%1 / 34
1 Montageanleitung SOKO Sonic Buzzer SIPLACE D4 SOKO
Ausgabe 10/2007
18
SOKO 2 Assembly instructions SOKO Sonic Buzzer SIPLACE D4
10/2007 Edition
19
2 Assembly instructions
SOKO Sonic Buzzer SIPLACE D4
2.1 Functionality / Features
When the SIPLACE encounters pick-up error and the SIPLACE does not stop, the tower light
flashes but the buzzer is off.
When the SIPLACE stops due to malfunctions, the tower light is permanently on and the buz-
zer sounds.
When the SIPLACE encounters pick-up error and the machine stops, the tower light is perma-
nently on and the buzzer sounds.
To reset the sonic buzzer press any stop button on the machine or solve the problem.
2
The buzzer will sound only when the white tower light flashes more than 3 seconds. The frequency
is 0.5 seconds. 2
2
To adjust the loudness turn the knob on the speaker box. 2
2.2 Requirements
SIPLACE D4
Assembly kit for SOKO Sonic Buzzer D4 (00176089-xx).
2
2
2
2
2
2
2
2
2 Assembly instructions SOKO Sonic Buzzer SIPLACE D4 SOKO
10/2007 Edition
20
2.3 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with mains voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the assembly, always secure the machine to prevent access by other people and to pre-
vent it being switched on again. The procedure is described in the “Locking the machine…” sec-
tion of the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2
2
2
2