00196624-04_Service Manual WPC5_6_EN_01-2019 - 第139页

Service Manua l WPC5 / WPC6  Page 4-139 4.4 Performing a WPC Enduran ce Run After calibration, we rec omm end that you test the function b y performing a W PC endu rance run. ➢ Select Manual functions -> WPC enduranc…

100%1 / 143
Service Manual WPC5 / WPC6
Page 4-138
Confirm the new position at which the limit switch triggers with
Finish
(1).
Calibrating the limit switch +
Select the lifting axis (1).
Select the function
Calibrate limit switch +
and continue with the same procedure as that
used for calibrating the limit switch.
Service Manual WPC5 / WPC6
Page 4-139
4.4 Performing a WPC Endurance Run
After calibration, we recommend that you test the function by performing a WPC endurance run.
Select
Manual functions -> WPC endurance runs
.
Set a continuous run of 15 mins and start.
Service Manual WPC5 / WPC6
Page 4-140
4.5 Storing and Restoring Machine Data
Storing machine data
Log in as
Machine Service
.
Select
Sensors and Functions
(1) =>
Location
.
Select the relevant location (2).
Select the option
WPC Machine Data
(3).
Enter the WPC serial number (4) and select
Accept
.
Select
Save machine data
(5).
A dialog box for the machine data storage location will open.
Enter the required storage location and then save the machine data..