00196624-04_Service Manual WPC5_6_EN_01-2019 - 第48页

Service Manua l WPC5 / WPC6  Page 3- 48 3.6.3.3 Repla ce the Co ntroll er Board Spare Part • W PC5 Controller Board [03057377- xx] Removal / Install ation ➢ Make a backup copy of the machine data, if this is still possi…

100%1 / 143
Service Manual WPC5 / WPC6
Page 3-47
3.6.3 Control Unit
3.6.3.1 Instructions for Working with Control Units
3.6.3.2 Replace the Power Supply Board
Spare Part
WPC power supply board [03071546-xx]
Removal / Installation
Wear the ESD wristband.
Open the top and bottom locks and loosen the 4 screws fastening the front plate of the
power supply board.
Carefully pull the power supply board (see "3.6.3 Control Unit" [
3-47]) out of the control
unit.
Carefully insert the new power supply board.
Make sure that the power supply board engages properly.
Tighten the 4 screws fastening the front plate of the power supply board and lock the top
and bottom locks.
Settings
No settings are required.
Service Manual WPC5 / WPC6
Page 3-48
3.6.3.3 Replace the Controller Board
Spare Part
WPC5 Controller Board [03057377-xx]
Removal / Installation
Make a backup copy of the machine data, if this is still possible (*.xml). See "4.5 Storing and
Restoring Machine Data" [
4-140].
Wear the ESD wristband.
Unplug the CAN bus cable from the front of the controller board.
Loosen the 2 screws fastening the front plate of the controller board.
Unlock the top and bottom locks.
Carefully pull the controller board (see "3.6.3 Control Unit" [
3-47]) out of the control unit.
Make sure that the jumper on the new controller board is set identically to that on the
controller board to be replaced.
Position of the Jumper on the Controller
Board
Settings for
WPC5:
Jumper 1 to 3 Off, Jumper 4 On
Settings for
WPC6:
Jumper 1 and 3 Off, Jumper 2 and 4 On
Service Manual WPC5 / WPC6
Page 3-49
Carefully insert the new controller board.
Make sure that the controller board engages properly.
Tighten the 4 screws fastening the front plate of the controller board.
Lock the top and bottom locks.
Plug the CAN bus cable back into the front of the controller board..
Settings
Restore the previously saved *.xml file. See section.
For more information, refer to the Online Help for the station software. See "4.5 Storing and
Restoring Machine Data" [
4-140].