semi automatic MACHI NE PREPARAT ION MACH INE RELOCA TION Chapter Issue 1 Oct 02 Instal lation Manual 5. 1 1 MACHINE RELOCA TION General In the event of machine relocation , refer to the T echnical Reference Manual, T ra…

100%1 / 86
semi automatic
MACHINE PREPARATION
REMOVAL PROCEDURES
5.10 Installation Manual Chapter Issue 1 Oct 02
ProFlow Transit Bracket (if fitted)
Figure 5-8 ProFlow Transit Bracket
1. Remove the two M5 cap head screws and M5 washers (Items 3 and 4)
securing the ProFlow transit bracket (Item 7) to the bearing block (Item 5).
2. Remove the two M5 cap head screws and M5 washers (Items 3 and 4)
securing the ProFlow transit bracket (Item 7) to the motor support plate
(Item 1).
3. Remove the ProFlow transit bracket (Item 7).
This concludes the transit bracket removal procedure. Transit brackets and
associated fasteners should be stored for future reuse.
Item Description Item Description
1 Motor Support Plate 5 Bearing Block
2 Print Carriage 6 ProFlow Mounting Assembly
3 M5 Cap Head Screw 7 ProFlow Transit Bracket
4 M5 Washer
Print Carriage
ProFlow Mounting Assembly
ProFlow Transit
Bracket
Motor Support Plate
Bearing Block
semi automatic
MACHINE PREPARATION
MACHINE RELOCATION
Chapter Issue 1 Oct 02 Installation Manual 5.11
MACHINE RELOCATION
General In the event of machine relocation, refer to the Technical Reference Manual,
Transportation chapter for transit bracket fitment procedure.
Voltage Supply If a machine specified for a low voltage factory supply area is re-located to a
high voltage factory supply area, or vice versa, the following check is required:
Figure 5-9 Optional Filtration Unit - Voltage Check
Fitted Option Low Voltage Unit
(110V)
High Voltage Unit
(230V)
Vacuum Filtration Unit
semi automatic
MACHINE PREPARATION
MACHINE RELOCATION
5.12 Installation Manual Chapter Issue 1 Oct 02
Vacuum Filtration
Unit Option
In accordance with customer requirements, the optional onboard vacuum filtra-
tion unit is fitted to the machine in one of two configurations:
110 Volt Unit
230 Volt Unit
CAUTION
LOW VOLTAGE FILTRATION UNIT.
Filtration unit internal fuse (8A) is liable
to rupture if low voltage unit is connected to a high voltage factory supply.
110 Volt Unit If the printing machine is reconfigured from a low voltage factory supply setting,
to that of a higher voltage setting. The low volt optional vacuum filtration unit
(DEK Part No. 163557), must be replaced with a high voltage unit (Dek Part
No.163558).
NOTE
No apparent damage to the unit would occur, with the exception of the supply
cable temperature increasing and consequent rupturing of the unit internal fuse
(10A).
230 Volt Unit If the printing machine is reconfigured from a high voltage factory supply setting,
to a lower voltage setting. The high volt vacuum filtration unit must be replaced
with a low voltage unit.
NOTE
No apparent damage to the unit would occur, however the unit performance
would be greatly diminished.