YSM10_Mainte_E - 第74页

3-7 3 Periodic maintenance items n How to use ANC nozzle attaching / detaching tool (attaching nozzles) Attach nozzles at the nozzle station in the reverse order of detac hing. 1 Check the nozzle setting position. Check …

100%1 / 153
3-6
3
Periodic maintenance items
n
How to use ANC nozzle attaching / detaching tool (detaching nozzles)
1
Open the nozzle station shutter.
Open the [Unit] - [Head] screen and press
the [Nozzle. Stn Shutter] button to open the
nozzle station shutter.
54300-KMG-00
2
Set the tool on the nozzle station.
1. Press the emergency stop button to open
the machine safety cover.
2. Set the tool vertically on the nozzles at
the nozzle station aligning the position of
nozzles to be detached.
3. Check that the tool is set to nozzles
securely.
53308-KMG-00
3
Raise the tool up.
Raise the tool up vertically and slowly.
53309-KMG-00
n
NOTE
Raise the tool up vertically and slowly to avoid the
nozzle tip from hitting the shutter, etc.
c
CAUTION
If raising the tool up fast and forcibly, nozzles or the
nozzle station may be damaged.
4
Close the nozzle station shutter.
Press the [Nozzle. Stn Shutter] button again
and close the nozzle station shutter.
Nozzle station - Opening the shutter
[Nozzle.Stn Shutter] button
Step1
Step 2
Setting the tool
Set the tool vertically aligning
nozzles to be detached.
Check that the tool is set to
nozzles securely.
Step 3
Raising the tool up
Raise the tool up vertically to avoid the
nozzle tip from hitting the shutter.
3-7
3
Periodic maintenance items
n
How to use ANC nozzle attaching / detaching tool (attaching nozzles)
Attach nozzles at the nozzle station in the reverse order of detaching.
1
Check the nozzle setting position.
Check that other nozzles are not set to the nozzle storage position and the setting position is correct.
n
NOTE
Regarding the nozzle setting position, check the nozzle placement position label attached in the machine or the
machine setting.
2
Set the nozzles to the tool.
c
CAUTION
The positioning pins are in each nozzle storage position at the nozzle station to avoid setting the incorrect types of
nozzle and the incorrect nozzle setting direction. Take precautions about the nozzle setting position and the nozzle
setting direction when setting the nozzles to the tool.
3
Open the nozzle station shutter.
1. Press the emergency stop button to open the machine safety cover.
2. Open the [Unit] - [Head] screen and press the [Nozzle. Stn Shutter] button to open the nozzle station
shutter.
4
Set the tool on the nozzle station.
1. Set the tool that the nozzles were set in Step 2 to the relevant position of the nozzle station.
2. Check that the nozzles are set securely to the nozzle station.
5
Close the nozzle station shutter.
Press the [Nozzle. Stn Shutter] button again and close the nozzle station shutter.
6
Raise the tool up.
Raise the tool up vertically and slowly and detach the nozzles from the tool.
n
NOTE
Raise the tool up vertically and slowly to avoid the nozzle tip from hitting the shutter, etc.
c
CAUTION
If raising the tool up fast and forcibly, nozzles or the nozzle station may be damaged.
3-8
3
Periodic maintenance items
1.3 Recognition unit
1.3.1 Cleaning the multi-camera lighting's protective glass
Adhered dust, etc., on the multi-camera lighting's protective glass can cause component recognition errors. To
prevent this, it is recommended to inspect and clean the cover in a periodic manner.
1
Blow off dust on the lighting's
protective glass.
1. Press the emergency stop button to open
the machine safety cover.
2. Remove the dust on the lighting's
protective glass with a blower brush.
53310-KMG-00
TIP
A blower brush is available as an option.
2
Wipe the lighting's protective glass
with a cloth.
Wipe the lighting's protective glass with a
cloth which has been dampened with a
small amount of lens cleaner.
53311-KMG-00
n
NOTE
Use a lint-free cleaning cloth or paper wiper.
A lens cleaner is supplied with the machine. Do not use
other type of cleaner.
n
NOTE
If contaminants cannot be removed completely even
after performing the work stated above, clean the
backside of the protective glass or the lighting referring
to "4.1.2 Cleaning the multi-camera lighting unit" in this
Chapter.
Step 1
Blowing off dust with blower brush
Protective glass
Blower brush
Step 2
Wiping lighting's protective glass with lint-free cloth
Lint-free cloth