00191021-02 - 第102页
2 Functions for the Adj ustment of the Machine User’s Manual Test Program S ITEST 2.7 Wafflepack Changer Functions Software Version 403.xx Edit ion 12/97 2 - 38

User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.7 Wafflepack Changer Functions
2 - 37
●
In the "Axis" field activate the radio button of the axis (feed axis or lifting axis) for which you wish to
perform settings or carry out checks.
●
If you wish to change, measure or teach the value for the transfer position (component pick-up posi-
tion from the wafflepack tray), activate the radio button of the feed axis first.
●
Click on the appropriate button in the "Transfer position" field and carry out the steps required for the
selected function.
●
If you wish to change the zero point position, click on the
Teach
button in the "Zero point cor.value"
field and move the active axis to the desired position using the arrow keys. When the teaching proce-
dure is completed, a message box is displayed.
●
Click on the
Yes
button if the current position is to be accepted as the new zero point.
●
If you wish to check the position of a limit switch or of the reference Bero, remove all tray carriers from
the tray storage unit first.
●
Click on the button of the desired function in the "Check position" field and carry out any activities that
may be required during the check.

2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.7 Wafflepack Changer Functions Software Version 403.xx Edition 12/97
2 - 38

User’s Manual Test Program SITEST
Software Version 403.xx Edition 12/97
3 - I
Contents
Page
Calibration Functions
3.1 Preparation for the Performance of the Calibration Functions . . . . . . . . . . . . . . . . . . . . 3 - 3
3.2 Complete Calibration of the Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 5
3.3 PCB Camera Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 7
3.4 RV Camera Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 - 9
3.5 Calibration of the Machine Zero Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 11
3.6 Verification of the Calibration Tool Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 13
3.7 Calibration of the RV Nozzle Changer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 15
3.8 Calibration of the IC Nozzle Changer (SIPLACE 80F4) . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 19
3.9 Calibration of the IC Camera (SIPLACE 80F4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 21
3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4). . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 23
3.11 Calibration of the Coplanarity Laser Module (SIPLACE 80F4). . . . . . . . . . . . . . . . . . . . 3 - 25
3.12 Measuring the Position of PCB Reference Corner I
(and that of PCB Reference Corner II) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 27
3.13 Measuring the Pick-Up Positions of Tracks 1 and 120 . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 31