3 Calibration Functions User’s Manual Test Program S ITEST 3.6 Verification of the Calibration Tool Position Software Version 403.xx Edition 12/97 3 - 14

100%1 / 178
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 403.xx Edition 12/97 3.6 Verification of the Calibration Tool Position
3 - 13
3.6 Verification of the Calibration Tool Position
In the main view click on the icon (for gantry 1 of SIPLACE 80S-20) or the icon (for the gantry
of SIPLACE 80F
4
)
to switch the screen display to the "Gantry" display (see Fig. 0.3.4).
Click on the icon to reach the "Calibrate positions" display (see Fig. 3.5.1).
Click on the
Approach
button in the "Calibration tool pos." field.
The active gantry moves the PCB camera over the calibration tool position. The screen display is
switched to the PCB camera.
Check whether the calibration tool fiducial is visible in the PCB camera’s field of view.
Press
ESC
to return the screen display to the normal program mode.
3 Calibration Functions User’s Manual Test Program SITEST
3.6 Verification of the Calibration Tool Position Software Version 403.xx Edition 12/97
3 - 14
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 403.xx Edition 12/97 3.7 Calibration of the RV Nozzle Changer
3 - 15
3.7 Calibration of the RV Nozzle Changer
NOTE
Verify that the calibration data for the PCB camera, segment offset
II
(RV-PCB camera offset) and machine
zero point have already been determined.
In the main view click on the icon or or to switch the screen display to the "RV head"
display (see Fig. 0.3.5) of the desired RV head.
Click on the icon to switch to the "RV nozzle changer" display.
Fig. 3.7.1 "RV nozzle changer" Display
Overview of the functions:
Complete calibration to determine the x and y-positions for each magazine
Calibrate magazine to determine the x and y-positions for the current magazine
Calibrate pick-up height to determine the pick-up height for the current magazine
Pick up to remove the nozzle from the selected garage of the current magazine
Return to deposit the nozzle in the selected garage of the current magazine
Garage number... to open the input box for the garage number