User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 403.xx Edition 12/97 3.9 Calibration of the IC Camera (SIPLACE 80F4)
3 - 21
3.9 Calibration of the IC Camera (SIPLACE 80F
4
)
Carry out the preparatory steps proceeding as described in section 3.1.
In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "IC head /
IC camera" display.
Fig. 3.9.1 "IC head / IC camera" Display
Overview of the functions:
Calibrate IC head / camera to calibrate the IC head and the IC camera
Illumination values... to display the illumination values
(Normally, the illumination values do not need to be changed.
Changing the values in a non-expert manner will lead to
incorrect calibration results).
Display camera coefficient... to display the IC camera values determined
IC sleeve/RV camera offset... to display the offset between IC sleeve and RV camera in x and
y-direction, determined during calibration
Display camera and focus position... to display the camera position and focus height determined
3 Calibration Functions User’s Manual Test Program SITEST
3.9 Calibration of the IC Camera (SIPLACE 80F4) Software Version 403.xx Edition 12/97
3 - 22
Click on the
Calibrate IC head / camera
button.
The complete calibration will now be performed.
If you wish to view the values determined after the completion of the calibration procedure, click on the
Display camera coefficient...
button.
If you wish to view the values for the camera position and focus height, click on the
Display camera
and focus position...
button.
A comparison of the current versus the previous camera data (camera position in x and y-directions
and focus height) is displayed.
NOTE
The x and y-values of the current camera position are also displayed in the "Camera position" field.
Click on the icon to return to the main view.
User’s Manual Test Program SITEST 3 Calibration Functions
Software Version 403.xx Edition 12/97 3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4)
3 - 23
3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F
4
)
Carry out the preparatory steps proceeding as described in section 3.1.
In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "Flip-chip camera"
display.
Fig. 3.10.1 "Flip-chip camera" Display
Overview of the functions:
Calibr. flip-chip camera to calibrate the Flip-Chip camera
Illumination values... to display the illumination values
(Normally, the illumination values do not need to be changed.
Changing the values in a non-expert manner will lead to incorrect
calibration results).
Display camera coefficient... to display the Flip-Chip camera values determined
Display focus position... to display the camera position and focus height determined