4 Mapping User’s Manual Test Program S ITEST 4.1 Preparatory Steps for the Mapping Operation Software Version 403.xx Edition 07/97 4 - 4

100%1 / 178
User’s Manual Test Program SITEST 4 Mapping
Software Version 403.xx Edition 07/97 4.1 Preparatory Steps for the Mapping Operation
4 - 3
4.1 Preparatory Steps for the Mapping Operation
In the main view click on the Overall reference run button to perform a reference run of all gantry and
head axes.
Manually slide the PCB stopper to the center of the conveyor width.
Place the mapping plate onto the center conveyor.
NOTE
For RV and IC mapping a mapping plate with a dark, dull surface must be used.
In the case of dual conveyors, mapping must be performed for the right and left conveyor tracks.
CAUTION
!
On no account must the PCB clamping mechanism be actuated during PCB mapping
. If the glass map-
ping plate for PCB mapping is clamped, it may be damaged so severely, that it cannot be used any more.
4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 403.xx Edition 07/97
4 - 4
User’s Manual Test Program SITEST 4 Mapping
Software Version 403.xx Edition 07/97 4.2 PCB Mapping
4 - 5
4.2 PCB Mapping
NOTE
Verify that the calibration data for the RV camera, PCB camera, segment offset
II
(RV-PCB camera offset)
and the MA zero point have already been determined. Furthermore, prior to the performance of the mapping,
the width adjustment must have been calibrated.
In the main view click on the icon (for gantry 1 of SIPLACE 80S-20) or the icon (for the gantry of
SIPLACE 80F
4
)
to switch the screen display to the "Gantry" display (see Fig. 0.3.4).
Click on the icon to switch to the "PCB mapping" display.
Fig. 4.2.1 "PCB mapping" Display