4 Mapping User’s Manual Test Program S ITEST 4.1 Preparatory Steps for the Mapping Operation Software Version 403.xx Edition 07/97 4 - 4

User’s Manual Test Program SITEST 4 Mapping
Software Version 403.xx Edition 07/97 4.1 Preparatory Steps for the Mapping Operation
4 - 3
4.1 Preparatory Steps for the Mapping Operation
●
In the main view click on the Overall reference run button to perform a reference run of all gantry and
head axes.
●
Manually slide the PCB stopper to the center of the conveyor width.
●
Place the mapping plate onto the center conveyor.
NOTE
For RV and IC mapping a mapping plate with a dark, dull surface must be used.
In the case of dual conveyors, mapping must be performed for the right and left conveyor tracks.
CAUTION
∆
!
On no account must the PCB clamping mechanism be actuated during PCB mapping
. If the glass map-
ping plate for PCB mapping is clamped, it may be damaged so severely, that it cannot be used any more.

4 Mapping User’s Manual Test Program SITEST
4.1 Preparatory Steps for the Mapping Operation Software Version 403.xx Edition 07/97
4 - 4

User’s Manual Test Program SITEST 4 Mapping
Software Version 403.xx Edition 07/97 4.2 PCB Mapping
4 - 5
4.2 PCB Mapping
NOTE
Verify that the calibration data for the RV camera, PCB camera, segment offset
II
(RV-PCB camera offset)
and the MA zero point have already been determined. Furthermore, prior to the performance of the mapping,
the width adjustment must have been calibrated.
●
In the main view click on the icon (for gantry 1 of SIPLACE 80S-20) or the icon (for the gantry of
SIPLACE 80F
4
)
to switch the screen display to the "Gantry" display (see Fig. 0.3.4).
●
Click on the icon to switch to the "PCB mapping" display.
Fig. 4.2.1 "PCB mapping" Display