00191021-02 - 第46页

1 General Functions User’s Manual Test P rogram SITEST 1.4 Reference Run Software Version 403.xx Edition 12/97 1 - 10 1.4.4 Reference Run of IC Head (SIPLAC E 80F 4 ) ● In the main v iew click on the i con an d the n (if…

100%1 / 178
User’s Manual Test Program SITEST 1 General Functions
Software Version 403.xx Edition 12/97 1.4 Reference Run
1 - 9
1.4 Reference Run
Prior to starting to work with the test program it is necessary to perform a reference run of the gantry axes, the
head axes and, where available, also of the WPC axes.
1.4.1 Overall Reference Run
In the main view click on the
Overall reference run
button.
The reference run will be performed for all head and gantry axes.
1.4.2 Head and Gantry Reference Run of the Active Gantry
Example: Gantry, SIPLACE 80F
4
In the main view click on the icon and then (if required) the icon in order to reach the "Gantry
functions" display (see Fig. 0.3.4).
Click on the
Head reference run
button.
The reference run will be performed for all axes of the revolver head and the IC head.
Following the head reference run, click on the
Gantry reference run
button.
The gantry axes will perform the reference run.
NOTE
The steps described above also apply to gantries 1 and 2 of SIPLACE 80S-20.
The reference run will be performed for the head and gantry axes associated with the gantry selected.
1.4.3 Reference Run of RV Head
Example: Revolver head 1, SIPLACE 80S-20
In the main view click on the icon and then (if required) the icon in order to reach the
"RV head functions" display (see Fig. 0.3.5).
Click on the Head reference run button.
The reference run will be performed for all axes of the revolver head of gantry 1.
If you wish to close the nozzles and move the (center) sleeves to the 0-degree position, click on the
Swivel out segments / close noz. button.
1 General Functions User’s Manual Test Program SITEST
1.4 Reference Run Software Version 403.xx Edition 12/97
1 - 10
1.4.4 Reference Run of IC Head (SIPLACE 80F
4
)
In the main view click on the icon and then (if required) the icon to reach the "IC head func-
tions" display (see Fig. 0.3.6).
Click on the
Head reference run
button.
The reference run will be performed for all axes of the IC head.
1.4.5 Reference Run of WPC Axes (SIPLACE 80F
4
)
In the main view click on the icon and then (if required) the icon to reach the "WPC functions"
display (see Fig. 0.3.10).
Click on the
WPC reference run
button.
The reference run will be performed for all axes of the wafflepack changer.
User’s Manual Test Program SITEST 1 General Functions
Software Version 403.xx Edition 12/97 1.5 Toggling Cycle Mode On/Off
1 - 11
1.5 Toggling Cycle Mode On/Off
For toggling the cycle mode function, click on General functions --> Cycle mode... on the menu bar,
or press the key combination
ALT
+
t
.
The "Cycle mode" setting box opens.
Click on the On radio button to activate the cycle mode, or on the Off radio button to deactivate the
cycle mode.