2 Functions for the Adj ustment of the Machine User’s Manual Test Program S ITEST 2.1 Axis Functions Softw are Version 403.xx Edition 12/97 2 - 10 ● Change the valu e as req uired an d confir m your e ntry by cl icking o…

100%1 / 178
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.1 Axis Functions
2 - 9
Adjusting the P gain for the z-axis:
Click on the
Adjust P-gain...
button. The following setting box opens.
Select the lines containing the parameters you wish to edit by double-clicking, and edit the value or
the positioning type as required
.
Once you have completed all desired entries or changes, click on the
Start
button in the setting box.
The continuous run for the adjustment of the P gain is started, and a dialog box displaying the start
time opens.
Click on the
Cancel
button in the dialog box to terminate the continuous run.
The completion time of the continuous run is displayed in the dialog box. The label of the "Cancel"
button changes to "OK".
Close the dialog box by clicking on
OK
.
Adjusting the P gain for the dp-axis:
To adjust the P gain of the dp-axis, click on the
Adjust P-gain...
button.
The setting box for the parameter group opens.
All further steps are the same as described in section 2.1.1, page 2 - 6.
If you wish to index the star axis in the continuous run mode, click on the
Star continuous run
button
in the "Star axis" display.
The input box below opens.
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.1 Axis Functions Software Version 403.xx Edition 12/97
2 - 10
Change the value as required and confirm your entry by clicking on
Accept
.
The continuous run is started and a dialog box displaying the start time opens.
Click on the
Cancel
button in the dialog box to terminate the continuous run.
The completion time of the continuous run is displayed in the dialog box. The label of the "Cancel"
button changes to "OK".
Close the dialog box by clicking on
OK
.
If the calibration tool position is to be approached, click on the
Calibration tool pos.
button.
To index the star, continue to click on the
Step star axis
button until the number of the desired
(center) sleeve is displayed in the bottom position (see Fig. 2.1.2).
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.1 Axis Functions
2 - 11
2.1.3 IC Head Axis Functions
In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "IC head, axis
functions" display.
Fig. 2.1.3 "IC head, axis functions" Display
To perform the individual functions, proceed as follows:
NOTE
Since the layout of some of the setting boxes is identical or similar to that for the gantry axis functions and RV
head axis functions (see section 2.1.1 and section 2.1.2), these boxes will not be described and displayed
again in this section.
In the "Axis" field activate the radio button for the axis to be adjusted ("z-axis" or "d-axis").
Select the
Axis reference run
function if the axis has not been referenced yet.
To move the axis to a given position in one operation, click on the
Position axis..
button. The setting
box for the "Target position" and "Positioning type" opens.
All further steps are the same as described in section 2.1.1, page 2 - 4.