00191021-02 - 第81页

User’s Manual Test Program S ITEST 2 Functions for the Adjustment of the Machine Software Version 403.xx Edition 12/97 2.2 Head Board 2 - 17 2.2 Head B oard The func tions of the hea d board are used t o test the r espec…

100%1 / 178
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.1 Axis Functions Software Version 403.xx Edition 12/97
2 - 16
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.2 Head Board
2 - 17
2.2 Head Board
The functions of the head board are used to test the respective placement head. Normally, the test is per-
formed with the aid of the "Head continuous run" function (see display "RV head functions", Fig. 0.3.5).
2.2.1 Functions of the RV Head in the Placement and Pick-Up Circuits
If you wish to test the head functions in the placement and pick-up circuits, click on the icon in
the "RV head" display (see Fig. 0.3.5) to switch to the "Head board RV head, placement and
pick-up circuit".
Fig. 2.2.1 "Head board RV head, placement and pick-up circuit" Display
Legend pertaining to
Fig. 2.2.1
to switch the vacuum on/off
to switch the air-kiss function at the placement station on/off
version number of the firmware
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.2 Head Board Software Version 403.xx Edition 12/97
2 - 18
To switch the vacuum on/off, activate the appropriate radio button in the "Vacuum" field.
To switch the air-kiss function on/off, activate the appropriate radio button in the "Air kiss" field.
NOTE
Prior to the execution of the functions "Step star axis" and "Vacuum test RV head" described below, a
head reference run must have been performed on the RV head (see section 1.4.3).
To index the star, continue to click on the
Step star axis
button until the number of the desired
(center) sleeve is displayed above the arrow (see Fig. 2.2.1).
To measure the vacuum values of all nozzles with the vacuum both switched on and off, click on the
Vacuum test RV head
button. The measured values are displayed in a dialog box.
Close the dialog box by clicking on
OK
.
To move the stepper motor into neutral position (starting position), click on the
Initialize stepper
motor
button.
To check the vacuum, click on the
Test vacuum
button.
The values measured with the nozzle both open and closed, are displayed above the button.
To measure the current vacuum values in the placement and pick-up circuits, click on the
Measure
vacuum