00900223-01_ID_OIS_SIS_17.0_R19-2_EN_DE - 第26页

ASM OIS/SIS Datab ases 17.0 (R19 -2) / Interf ace Description 11/2019 Edition 26 4.5.1.21 Panel Table Panel OIS name Data type Byte CI I P Reference (from BOARD table). Note: This reference may occur several times since …

100%1 / 150
ASM OIS/SIS Databases 17.0 (R19-2) / Interface Description 11/2019 Edition
25
Number of consecutive pickup attempts that
does not cause an track-empty error.
sPickupRetries
int
4
Version of the information source for the reject
data
sAttritionInfoVersion
int
4
Definition of sRejectVacuum
sRejectVacuum = SUM(sAbsenceAfterPick, sComponentAbsenceBeforePlacement,
sTreatmentError, sDroppedError, sComponentAbsenceAfterPlacement,
sPickupRetries)
Definition of sRejectIdent
sRejectIdent = SUM(sComponentMaterialDefect, sIdentError)
Definition of sPlacedComponents values
-1:
Undefined for all data records issued by a station with a station software version < 708
0:
No successful placement (i. e. pass-through mode, canceled board etc.)
n:
n successful placements
Definition of sAttritionInfoVersion values
0:
Reject data comes from a station software version < 708
1:
Reject data comes from astation software version >= 708
4.5.1.20 CompPosition Table
CompPosition
OIS name
Data type
Byte
CI
I
P
Identification number of the station
(reference to STATION table)
lId
int
4
Reference number of the entry
lIdPosition
bigint
8
Table/location from which the component was
retrieved
ucTable
tinyint
1
Track number
sTrack
smallint
2
Tower (MTC only, otherwise dummy)
ucTower
tinyint
1
Level (WPC or MTC only, otherwise dummy)
sLevel
smallint
2
Division
sReceptacle
smallint
2
Identification number of the component name
(available with station software version 701 and
higher)
lPartNumber
int
4
Identification number of the component shape
name (available with station software version
701 and higher)
lComponentShape
int
4
SIPLACE Pro number for feeder type (available
with station software version 701 and higher)
lFeederType
long
4
Time when the data is written. Local server time
dtCreated
datetime
8
Unique feeder ID
strFeederId
nvarchar(128)
256
ASM OIS/SIS Databases 17.0 (R19-2) / Interface Description 11/2019 Edition
26
4.5.1.21 Panel Table
Panel
OIS name
Data type
Byte
CI
I
P
Reference (from BOARD table).
Note: This reference may occur several times
since a board may have several panel groups.
lIdPanel
bigint
8
Count of produced panels
lCountProduced
int
4
Count of omitted panels
lCountOmitted
int
1
Encoding whether the panel entry is intended to
be counted as assembled PCB (based on
SIPLACE Pro setting)
CountAsAssembledPCB
tinyint
2
Name of the concerned placement list
strPlacementListName
nvarchar(256)
512
Definition of CountAsAssembledPCB values
0:
Undefined
1:
True
2:
False
4.5.1.22 SpliceEvent Table
SpliceEvent
OIS name
Data type
Byte
CI
I
P
Identification number of the station
(reference to STATION table)
lId
int
4
Table/location from which the component was
retrieved
ucTable
tinyint
1
Track number
sTrack
smallint
2
Division
sDivision
smallint
2
Identification number of the component name
lPartNumber
int
4
Date/time at which the data record was created.
Station time
dtTime
datetime
8
Time when the splice occurred at the station
dtSpliceTime
datetime
8
Time when the data is written. Local server Time
dtCreated
datetime
8
Sequence ID (internal use)
lIdSequence
bigint
8
ASM OIS/SIS Databases 17.0 (R19-2) / Interface Description 11/2019 Edition
27
4.5.1.23 ProcessingLocation Table
The table is filled after configuring the station. If the station is no longer registered after cleaning up
the database (task approximately every 40 days), the entries are deleted.
ProcessingLocation
OIS name
Data type
Byte
CI
I
P
Entry Identifier
ld
bigint
8
Identification number of the station
(reference to STATION table)
lId
int
4
Processing area 1 / 2 (Printer machines always
have only 1)
ProceesingArea
tinyint
1
Physical number of conveyor
1 right / 2 left. Single conveyor = 1
Conveyor
tinyint
1
Logical assignment of conveyor (i.e. printer
back-to-back solution)
VirtualLine
tinyint
1
Time when the data is written. Server Time
dtCreated
datetime
8
4.5.1.24 PlocAvailability Table
As of station software version 712.0, this table contains the processing location states explicitly
sent by the station.
PlocAvailability
OIS name
Data type
Byte
CI
I
P
Entry Identifier
ld
bigint
8
Reference to ProcessingLocation table ->(Id)
PlocId
bigint
8
Reference to EVENT table -> (lIdSequence)
EventSequenceId
bigint
8
Timestamp (localtime) from station when state
was entered
CurrentStateBegin
datetime
8
Current E58 State Code
CurrentStateCode
nvarchar(4)
10
Previous E58 State Code
PreviousStateCode
nvarchar(4)
10
Time when the data is written. Server Time
dtCreated
datetime
8
Reference to AssistCollection table
IdAssistList
bigint
8
E58 State Codes:
E10 States
Substate E58
State description
0
No value entered
1000 (Productive)
1000
PRD\Default
1100
PRD\Regular work
11a1
PRD\Regular work: Hardware occupied
11b1
PRD\Pass-Through
1400
PRD\Engineering runs
2000 (Standby)
2000
SBY\Default
20a0
SBY\External data missing
22a0
SBY\No product: Blocked
22b0
SBY\No product: Starved
22b1
SBY\No product: No consumables
2300
SBY\No support tool
2400
SBY\Associated cluster module down
2500
SBY\No host
3000 (Engineering)
3000
ENG\Default