A1. Specifications
n
YC8 specifications
Item Specifications
Operating ambient temperature
Function guaranteed: 15 to 35°C
Accuracy guaranteed: 20 to 28°C
Operating ambient humidity 20 to 90% (no condensation), optimal range: 50 to 60%
Noise level Under 78dB
Power requirement (voltage and frequency) 3-phase 200/208/220/240/380/400/416 VAC ± 10%, 50/60 Hz
Power capacity 3.2KVA
Average power consumption 0.64kW
Power cable (conductor cross-section area) 2.5 mm
2
or more
Overvoltage category *
1
Category III
Pollution degree *
1
Degree 2
Supply air pressure *
2
0.45MPa
Air flow rate 50Nl/min, Instantaneous maximum flow rate: 90Nl/min
Board transport height *
3
900 mm ± 10 mm
Data
Number of mounting points *
4
10,000 points
Number of part types 255 types per board
Number of fiducial marks *
5
128 sets per board
*1: Conforms to IEC60664-1.
*2: Clean, dry air passed through an air dryer and filter.
*3: Distance from the floor surface to the upper surface of conveyor belt.
*4: Decreases with the number of boards, blocks and fiducial marks.
*5: When using 2-point fiducial mode.
c

Conveyor's board sensors may fail to detect a production board if it has a slit or cutout.
n
NOTE
For more detailed information not listed above, please refer to specification sheets.
S-1

Index
A
Alarm buzzer 1-3
ATS15 1-10
Axis configuration 1-14
Board clamping method 2-23
Board production
Ending production 3-8
Pre-operation check 2-18
Resuming operation 3-6
Starting production 3-1
Starting the machine 2-19
C
CE marking i
Component supply section 1-9
Component trays 2-35
Connection between machines 1-3
Conveyor unit 1-13
Conveyor unit setup 2-23
Conveyor width 2-12
[Convey-out stop] button 3-8
[Cycle Stop] button 3-8
Data input unit 1-4
Dummy feeder iv
E
Emergency stop
Canceling emergency stop 2-1
Error
Clearing an error 2-2
Errors and troubleshooting 2-3
External setup power station 2-26
feeder 1-9
Feeder plate
Air connector 1-9
Power supply connector 1-9
feeder plates 1-9
[Feeder Setting] button 2-15
H
Head assembly 1-6
K
Keyboard 1-4
Machine main unit 1-1
Names and functions of major parts 1-1
Manual feeder operation 2-15
Manual head operation 2-14
Manual I/O operation 2-16
[Monitor] button 3-10
Mouse 1-4
N
Nozzle station 1-8
Nozzle types 1-7
Operation panel 1-4
[READY] button 2-1
Operation panel buttons 1-5
[ACTIVE] button 1-5
[EMERGENCY STOP] button 1-5
[ERROR CLEAR] button 1-5
[READY] button 1-5
[RESET] button 1-5
[START] button 1-5
[STOP] button 1-5
Operation screen 2-8
Menu button area 2-8
Status area 2-8
Operation speed 3-3
[Operator] button 2-20
P
Pallet 1-11
Setting a pallet 2-36
Password 2-20
Pick Rate Warning 3-24
Pickup position offset 3-22
Power switch 1-3,2-19
Turning power off 3-8
Pressure gauge 1-3
Production monitors 3-10
Push-up pin 2-25
R
Recognition system 1-13
Return-to-origin 2-19
S
Safety ii
Safety cover 1-3
Safety message vii
Setup screen 2-11,3-2
[Check Nozzles] button 3-3
[Feed Bulk] button 3-3
[Measure Nozzles] button 3-3
[Required Nozzles] button 3-3
[Required Parts] button 3-2
Signal light 1-3
Specifications A-1
T
Tape feeder
Disposing of used top tape 3-4
Operation check 2-41
Setting a tape feed pitch 2-31
Settings on the mounter side 2-37
Setting the tape 2-26
Tray changer 1-10
Tray components 2-35
U
Unit screen 2-12
W
Warm-up 2-21
[Warm Up] button 2-21
Warning labels xi
"watch-and-wait" mode 3-26
Version 1.00
Operators Manual July 2012