00194716-04_AI_Abwurfbehaelter_Abfrage_X-D3_de_en - 第70页
Installation Connecting the Sensors to the CAN Nodes Overview of sensor park position 70 Option Verify Reject Bin Option Abfrage Abwurfbehälter Connecting the se nsor connector to the CAN node s infrastructure 1 Connecto…

Installation
Overview of sensor park position Connecting the Sensors to the CAN Nodes
Option Verify Reject Bin Option Abfrage Abwurfbehälter 69
3.1.4 Overview of sensor park position
► Sensors which are not used must be fixed into the park position.
3.2 Connecting the Sensors to the CAN Nodes
The main task of the CAN node is to control the tape cutter.
The cabels (2) to (5) (see section "3.2.1 Circuit Diagram for Sensors with CAN Nodes" [ ➙ 71]) are run
as a default in the component feed device and connected to the CAN node option. The connectors can
therefore be found on the back of the component feed device, above the empty tape duct.
► Connect the X series/HF R2 cable for the reject bin [03022078-xx] to the cable from the CAN nodes
option [03035229-xx].
Sensor park position
for HF
Sensor park position
for X series reject bin
Sensor park position
for TwinHead with MTC
CAUTION
1-Wire-Hub or CAN node
Although some component feed devices already have the cables for the CAN node module
ready, the old version of the cutter control is still used. In this case, you either need to convert
to the CAN node module or use the 1 wire hub. Mixed configurations in the same machine are
not possible.
► Old cutter control board: [03006411-xx]
► New cutter control board for CAN node module [03052927-xx]
► From machine number B752 the component feed device has been converted fully to the
CAN node option.
► For conversion to the CAN nodes option, please contact your Siemens Service team.

Installation
Connecting the Sensors to the CAN Nodes Overview of sensor park position
70 Option Verify Reject Bin Option Abfrage Abwurfbehälter
Connecting the sensor connector to the CAN nodes infrastructure
1 Connector X2*q
Cable from CAN nodes [03035229-xx]
2 Cable X series/HF R2: reject bin
[03022078-xx]
3 Position of unused cable at CAN nodes. 4 Sensor S1 on the reject bin 6x6 for C&P20
and CPP
5 Sensor S2 on the nozzle reject bin C&P20
and CPP
6 Cable from CAN nodes to nozzle changer

Installation
Circuit Diagram for Sensors with CAN Nodes Connecting the Sensors to the CAN Nodes
Option Verify Reject Bin Option Abfrage Abwurfbehälter 71
3.2.1 Circuit Diagram for Sensors with CAN Nodes
Circuit diagram for component feed device with CAN nodes for cutter
1 CAN nodes 2 Cable: nozzle changer control
W1: nozzle changer row 1
3 Cable: reject bin sensors X2*q 4 Cable: nozzle changer control
W2: nozzle changer row 2
5 Cable: solenoid valve for nozzle station