ES40-60-AR10-A.pdf - 第2页
Port size M5 x 0.8 Pressure gauge port size * 1 1/16 Fluid Air Ambient and fluid temperature –5 to 60 ° C (with no freezing) Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.7 MPa Co…

2
1
Symbol Description
NNq
Option
∗
1
a Mounting
Nil
Without mounting option
B
∗
2
With bracket
H
With set nut (for panel mount)
+
b Pressure gauge
Nil
Without pressure gauge
G
∗
3
Round type pressure gauge (without limit indicator)
+
Nw
Semi-standard
c Set pressure
∗
4
Nil
0.05 to 0.7 MPa setting
1
0.02 to 0.2 MPa setting
+
d Exhaust mechanism
Nil
Relieving type
N
Non-relieving type
+
e Flow direction
Nil
Flow direction: Left to right
R
Flow direction: Right to left
+
f Knob
Nil
Downward
Y
Upward
+
g Pressure unit
Nil
Name plate and pressure gauge in SI units: MPa
Z
∗
5
Name plate and pressure gauge in imperial units: psi
Option and Semi-standard Symbol Selection
Regulator
AR10-A
Symbol
Regulator
How to Order
AR10 M5
wq
A
• Select one each for a to g.
• When more than one specification is required, indicate in alphanumeric order.
Example) AR10-M5BG-1NR-A
∗1 Options are not assembled and supplied loose at the time of shipment.
∗2 Assembly of a bracket and set nuts
∗3 A 1.0 MPa pressure gauge will be fitted. It is not assembled and supplied loose at the time of shipment.
∗4 Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.
∗5 This product is for overseas use only according to the new Measurement Act. (The SI unit type is provided for use in Japan.)
AR10-A
13
A

Port size M5 x 0.8
Pressure gauge port size
*
1
1/16
Fluid Air
Ambient and fluid temperature –5 to 60°C (with no freezing)
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa
Construction Relieving type
Weight 0.06 kg
Standard Specifications
Bracket assembly
*
1
AR12P-270AS
Set nut AR12P-260S
Round type pressure gauge
*
2
G27-10-R1
Options/Part No.
*1 Assembly of a bracket and set nuts
*2 1.0 MPa pressure gauge
*1 Use a bushing (part no.: 131368) when connecting the R1/8 pressure gauge to the Rc1/16.
0.6
0.5
0.4
0.3
0.2
0.1
0
0 25 50 75 100 125 150
Outlet pressure [MPa]
Flow rate [L/min (ANR)]
Flow Rate Characteristics (Representative values)
AR10-A
M5
Condition: Inlet pressure of 0.7 MPa
0
0.15
0.2
0.25
0.3
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Outlet pressure [MPa]
Inlet pressure [MPa]
Set point
Pressure Characteristics (Representative values)
AR10-A
Conditions: Inlet pressure of 0.7 MPa,
Outlet pressure of 0.2 MPa,
Flow rate 20 L/min (ANR)
Dimensions
AR10-A
M
UD
J
F
2 x P1
(Port size)
CB
Q
V
T
N
S
R
A2 x P2
(Pressure gauge port size)
IN
OUT
Bracket
(Option)
IN
OUT
W
Panel mounting dimensions
Plate thickness
AR10-A: MAX.3.5
*1 The dimension of B is the length when the filter regulator knob is unlocked.
Option Round type pressure gauge
Dimensions
Center of piping
H
J
Model
Standard specifications
Optional specifications
Round type pressure gauge
Bracket mount
Panel mount
P1 P2 A B
*
1
C D F J
H J
M N Q R S T U V W
AR10-A
M5 x 0.8 1/16 25 47.4 11 12.5 M18 x 1 12.5
ø
26 26 25 28 30 4.5 6.5 40 2 18 18.5
14
Regulator AR10-A Series
A

0.4 MPa Setting
The setting specification is 0.4 MPa. When a pressure gauge is included, the display will show a range from 0 to 1.0 MPa.
Applicable Model
Model
AR10
Port size M5
AR 10 X406M5 A
0.4 MPa setting
wq
*2 Options B, G, H are not assembled and supplied loose at the time of shipment.
*3 Assembly of a bracket and set nuts.
*4 A 1.0 MPa pressure gauge will be fitted.
*5 This product is for overseas use only according to the new Measurement Act. (The SI unit type is provided for use in Japan.)
*1 Pressure can be set higher than the specification pressure in some cases, but use
pressure within the specification range.
Symbol Description
Body size
10
NNq
a Mounting
Nil
Without mounting option
Option
*
2
B
*
3
With bracket
H
With set nut (for panel mount)
+
b
Pressure gauge
*
4
Nil
Without pressure gauge
G
Round type pressure gauge (without limit indicator)
+
Nw
Semi-standard
c
Exhaust mechanism
Nil
Relieving type
N
Non-relieving type
+
d Flow direction
Nil
Flow direction: Left to right
R
Flow direction: Right to left
+
e Knob
Nil
Downward
Y
Upward
+
f Pressure unit
Nil
Name plate and pressure gauge in SI units: MPa
Z
*
5
Name plate and pressure gauge in imperial units: psi
Caution
• The AR10 comes with a backflow function as a standard feature.
When using the AR10 as with backflow function, backflow may
not occur with the set pressure of 0.15 MPa or less.
Specifications
Made-to-order part no.
-X406
Proof pressure
[MPa] 1.5
Maximum operating pressure [MPa
] 1.0
Set pressure range [MPa]
*
1
0.05 to 0.4
• Select one each for a to f.
• When more than one specification is required, indicate in alphanumeric order.
Example) AR10-M5BG-NR-A-X406
AR10 Regulator
Made to Order
Please contact SMC for detailed dimensions, specifications and lead times.
Option and Semi-standard Symbol Selection
15
A