TM1549_Document of Wait Across Machine Function.pdf - 第2页
SMT Software Engineeri ng Group IMOperationsYAMAHAMOTORCO. ,LTD. MDOC-SOFT 50038 2/ 11 1.Introductio n The target model and the obj ect version are as f ollows . T ab le1T arget…

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT500381/11
Aboardwaitacrossthemachinefunction
Contents
A board wait across the machine function..................................................................................... 1
1. Introduction................................................................................................................................ 2
2. Summary ................................................................................................................................... 2
3. Limitations ................................................................................................................................. 2
4. Basic Specifications................................................................................................................... 3
5. Settings...................................................................................................................................... 4
5.1. Way of Settings................................................................................................................... 4
6. Error messages ......................................................................................................................... 5
7. Appendix.................................................................................................................................... 7
7.1. Automatic settings............................................................................................................... 7
7.2. Manual settings................................................................................................................... 9
7.3. The board dimensions specifications.................................................................................11

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT500382/11
1.Introduction
The target model and the object version are as follows.
Table1TargetmodelandObjectversion
Item Object Remarks
Target Model YS12 Series mounter, YS100, YS88, YS24
YG12 Series mounter
Object version V3.10STD R1.000 or later
2.Summary
A board can stay between the downstream machine and the upstream machine in this version
(Refer to Fig.2.1). By this function, a large size board which could not stay on the waiting
position can stay there because the board can be transferred to the waiting position, and the
transfer cycle time can be improved.
Fig.2.1Aboardwaitacrossthemachine
3.Limitations
This function does not work other than “ADVANCED_GATE".
Only when the “ADVANCED GATE 2” is used as the transfer signal cable, this function
becomes effective. When this function is used other than “ADVANCED GATE 2” as the
transfer signal cable, interlock errors etc occur, and normal operation cannot be done.
When this machine is with the buffer conveyor (include d-YTF) in the downstream side,
“Wait across the machine” function is not available in the downstream side.
This Machine
Upstream
Machine
Board Board Board
Downstream
Machine

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD.
MDOC-SOFT500383/11
4.BasicSpecifications
A) Abouttheproductionboardcount
The number of producted board is counted up when the board reachs at the exit position as
before. When this function is used, the number of producted board is counted up when the
board reachs at the exit sensor because the board cannot be stopped and be tranferred to
the downstream machine.
B) Aboutthelog
When there is a board between the downstream machine and the upstream machine (“the
baord wait across the machine” state), the board is treated as a board of the downstream
machine. Therefore, the transfer time from the “the baord wait across the machine” state to
the board fixing position, is measured as transfer cycle time of the downstream machine.
The transfer time of the upstream machine is displayed by reaching time to the exit position
as before.
C) Abouttherecoverymethodafterthetransfererror
When the transfer error occurred, according to the instructions of the error message, please
move the board to the transfer destination position and restart auto-running.
When the board is stucked between machines, “Ea7337: BOARD TRANSFER ERROR” is
displayed, please move the board to the wait position of the downstream machine and
restart auto-running (cf. figure 4.1).
About the other transportation errors, please refer to "Chapter.6. Error message."
Fig.4.1Recoverymethodafterthetransfererror
This Machine
The board is stucked
between
machines
, and the transfer error
“Ea7337” occurred.
This Machine Upstream Machine
Upstream Machine