M6ex_ServiceManual_e.pdf - 第36页

3 Mechanical Section 3-2 Head Manifold Section Vacuum generator × 6 Silencer element × 6 Air filter Assy × 6 Filter element × 6 Solenoid valve ×12

100%1 / 100
3 Mechanical Section
3-1
3
Mechanical Section
3 Mechanical Section
3-2
Head Manifold Section
Vacuum generator × 6
Silencer element × 6
Air filter Assy × 6
Filter element × 6
Solenoid valve ×12
3 Mechanical Section
3-3
Head Manifold Section
Air Passage
To maintain the designed accuracy and component-placement rate of the machine, clean the air passage
between the air filter assy. and nozzle holder periodically.
ACTION: Carry out vacuum break operation for a few seconds with the nozzle removed.
Cleaning interval
Approx. once a week
Air Filter
ACTION: Remove the filter element from the air filter assy. and remove dust and dirt collected inside the assy. by air
blowing. Then, check the white air element for dirt. If it is excessively dirty, replace it with a new one. If air
filter assy. case is dirty, wash it with water or diluted neutral detergent, and dry it well. If there are cracks on
the case, replace the air filter assy., since the cracks will cause air leakage.
NOTE: Do not use alcohol or any organic solvents to wash the air filter assy. case. Using those solvents may cause
damage or degradation of the case because it is made of polycarbonate.
Inspection interval
Once a week, and when a choking error occurs
Part Name
Part No. Remark
FILTER ELEMENT LG0-M71A9-00X
AIR FILTER ASSY. LG0-M71A4-00X
Vacuum Generator
ACTION: Breakdown Visually check the silencer element, and if it is excessively dirty, replace it with a new one.
Also measure the maximum air pressure to inspect whether the vacuum generator can generate vacuum
properly.) Inspection for Head/Nozzle Clogging and Solenoid Valve
Inspection interval
Once a week
Part Name
Part No. Remark
SILENCER ELEMENT LG0-M71A8-00X
GENERATOR,VACUUM LG0-M71A3-00X