11 AJO-E-P (3) Remove the cap and the internal lid of the solvent tank. Fig. 10 (4) Replenish the solvent tank with additional industrial alcohol, using the replenishment container . T o avoid solvent drips, be sure to u…

10 AJO-E-P
3.1 Replenishment of Industrial Alcohol
• Use industrial alcohol as a cleaning solvent for this machine.
Refer to "1.2.1 Preparation for Cleaning" for the kinds of industrial
alcohol.
Work Procedure
(1) Shut down the power to the machine.
Fig. 8
(2) Open the safety doors on the rear side.
Fig. 9 Rear View
Industrial alcohol supply must be replenished with the power switch of
the machine being turned "OFF".
Only the person in charge of maintenance work should perform this
operation.
CAUTION
ON
tripped
reset
OFF
0
p
u
s
h
to
trip
Safety Door
Safety Doo
r
0412-001
3.1 Replenishment of Industrial Alcohol

11 AJO-E-P
(3) Remove the cap and the internal lid of the solvent tank.
Fig. 10
(4) Replenish the solvent tank with additional industrial alcohol, using the
replenishment container.
To avoid solvent drips, be sure to use the replenishment con-
tainer equipped with a nozzle.
If you spill solvent by mistake, clean it up with a rag as soon as
possible.
After cleaning up the spilt solvent, confirm that it has dried
completely and enough ventilation is provided. After that, turn
on the power switch of the machine.
Fig. 11
Cap
Internal Lid
Notice
0412-001
3.1 Replenishment of Industrial Alcohol

12 AJO-E-P
• The solvent tank must be filled up to the "MAX" line with industrial alco-
hol. (Approx. 1,500 ml or less)
If you fill the tank beyond the "Max" line, alcohol will overflow and drip out
of the tank, down to the floor.
Fig. 12 Solvent Tank
(5) After the replenishment of industrial alcohol, attach the internal lid of
the solvent tank and tighten the cap securely.
If air gets into the tube running between the solvent tank and the
discharge nozzle, industrial alcohol may not come out soon.
In this case, discharge a little amount of alcohol to let the air escape,
using the [Dispense Solvent (ON-OFF)] switch.
Fig. 13
Solvent
Internal Lid
Cap
Gasket
Joint
Leeway
MAX Line
Note
[Dispense Solvent (ON-OFF)] Switch
0412-001
3.1 Replenishment of Industrial Alcohol