FCM_User Reference Manual.pdf.pdf - 第160页

MIS User Re ference Manual 4022 5 91 96082 5-68 F CM Mult ifl ex 02.02 Er ro r co de Subsystem Error descripti on 53851 BV M T emperature Pin measurement failed 53853 X position out of r ange 53854 Y position out of r an…

100%1 / 306
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-67
MIS
Error code Subsystem Error description
44103 LAS Undefined Error (LAS-B8)
44104 Laser sensor not connected
44105 Laser measurement error
44106 Laser hardware error
44107 Laser protocol error
44108 Laser beam obstructed error
44109 Laser dirty error
44110 Laser checksum error on received data
44111 Laser time-out error on received data
44112 Laser parameter data damaged error
44113 Laser software error occured
44114 MUP did not move error
44115 LAS MUP has wrong notch size error
53307 BVM Measureline inconsistency
53790 BI Board id. configuration failed
53791 Barcode read failed
53792 Barcode read notification failed
53793 Board id. version not correct
53794 Param. save in param. file wrong
53795 Wrong configuration parameter
53796 Rate test startup failed
53797 Mailbox create failed
53798 Human interface not synchronized
53799 Human interface not started
53800 Close down failed
53801 Wrong AM id.
53802 No configuration entry found
53803 Time out
53804 Invalid response
53805 First board error
53806 Barcode not in range
53807 Board count failed
53808 No read was requested
53809 Barcode not matched in exist. order
53810 Validation of barcode not correct
53811 Barcode length not correct
53812 Illegal order handle
53813 Cannot start idle order
53849 BVM Fiducial/Badmark measurement failed
53850 DC Firmware SBIP timeout
MIS
User Reference Manual 4022 591 96082
5-68 FCM Multiflex 02.02
Error code Subsystem Error description
53851 BVM Temperature Pin measurement failed
53853 X position out of range
53854 Y position out of range
53857 Servo tracking error on X front
53858 Servo tracking error on X rear
53859 Servo tracking error on Y
53860 Servo power failure
53863 Servo amplifiers disabled
53864 Movement while no homing was done
53865 Right stop X axis not found
53866 Rear stop Y axis not found
53869 Index pulse X front not found
53870 Index pulse X rear not found
53871 Index pulse Y axis not found
53873 Left stop X axis not found
53874 Front stop Y axis not found
53877 X axis obstructed
53878 Y axis obstructed
53881 Communication error on X front
53882 Communication error on X rear
53883 Communication error on Y servo
53884 DC Firmware RS232 receive error
53885 Timeout on communication X front
53886 Timeout on communication X rear
53887 Timeout on communication Y servo
53888 DC Firmware RS232 transmit error
53916 DC not configured for DFA
53920 DC not configured for BMS
54272 GPM Miss SMD after pick
54273 Retain SMD after place
54274 Lost SMD before place
54275 Vacuum wrong, Cal. limit surpassed
54276 Requested X position out of range
54277 Requested Y position out of range
54278 Requested Phi pos. out of range
54279 Power dip during MUP down
54280 Servo tracking error on X axis
54281 Servo tracking error on Y axis
54282 Servo tracking error on Phi axis
54283 Servo power failure
4022 591 96082 User Reference Manual
02.02 FCM Multiflex 5-69
MIS
Error code Subsystem Error description
54284 GPM MUP down during movement
54285 Process error lost before align
54286 Servo amplifiers disabled
54287 Movement while no homing was done
54288 Right stop X axis not found
54289 Rear stop Y axis not found
54290 Zero EPD not found on Phi axis
54291 Pusher down during movement
54292 Index pulse X axis not found
54293 Index pulse Y axis not found
54294 Index pulse Phi axis not found
54295 PPU EEPROM Communication error
54296 Left stop X axis not found
54297 Front stop Y axis not found
54298 Home error Phi area is too large
54300 X axis obstructed
54301 Y axis obstructed
54302 Home error Phi area is too small
54304 Communication error on X servo
54305 Communication error on Y servo
54306 Communication error on Phi servo
54307 RS232 laser align link receive err
54308 Timeout on communication X servo
54309 Timeout on communication Y servo
54310 Timeout on communication Phi servo
54311 RS232 laser align link transmit er
54313 Flash EPROM table full
54314 Susp placement after machine error
54315 Flash EPROM zero offsets lost
54316 Timeout Smart Feeder
54317 Requested X position out of range
54318 Requested Y position out of range
54320 The MUP has become too slow
54321 The MUP has become too fast
54324 No PPU installed or wrong type
54325 PPU calibration checksum error
54328 X pos out of range due offset comp
54329 Y pos out of range due offset comp
54330 X pos out of range due MUP comp
54331 Y pos out of range due MUP comp