Pag e = DD HF =HF +DD/11 10 Modificati on Date Na m e No rm Check. Proj. Origin Date Crea. f. ERSA Hot flow 3/xx 18 .0 6. 200 9 =HF +DD/9 133 953- V00 Ot to-Schott-Straße 5 97 87 7 W ertheim Gm bH Plant designation Pr oj…

100%1 / 177
Page
=
DD
HF
=HF+DD/10
9
Modification Date
Name Norm
Check.
Proj.
Origin
Date
Crea. f.
ERSA
Hotflow 3/xx
18.06.2009
=HF+DD/8
133953-V00
Otto-Schott-Straße 5
97877 Wertheim
GmbH
Plant designation
Project name
14:15:1908.07.2010
+
file name (*.pdf)
133953-V00_100705
basic-project
-
Device list
Description
Device list
DIN_PSL_50_2_ERSA_LS1
Part numberPage/Path
=HF+CM-7M21 =HF+C1/375.05 6VEN-4650 outlet coolingaxial-fan
=HF+CM-7M24 =HF+C1/375.06 6VEN-4650 outlet coolingaxial-fan
=HF+CM-7M25 =HF+C1/375.07 6VEN-4650 outlet coolingaxial-fan
=HF+CM-7Y1
=HF+C1/370.08 155824 proportional valvecontroled cooling zone
=HF+C1-9A1 =HF+C1/365.02 152424 frequency inverter fans preheating bottom side
=HF+C1-9F1 =HF+C1/285.01 6EBSIA-16A-B2 preheating zone 1 bottom side
=HF+C1-9F2 =HF+C1/290.01 6EBSIA-16A-B2 preheating zone 2 bottom side
=HF+C1-9F3 =HF+C1/295.01 6EBSIA-16A-B2 preheating zone 3 bottom side
=HF+C1-9F4 =HF+C1/300.01 6EBSIA-16A-B2 preheating zone 4 bottom side
=HF+C1-9F5 =HF+C1/305.01 6EBSIA-16A-B2 preheating zone 5 bottom side
=HF+C1-9F6 =HF+C1/310.01 6EBSIA-16A-B2 preheating zone 6 bottom side
=HF+C1-9F7 =HF+C1/315.01 6EBSIA-16A-B2 preheating zone 7 bottom side
=HF+C1-9F11 =HF+C1/365.02 152433 frequency inverter fan preheating bottom side
=HF+C1-9F12 =HF+C1/285.07 6EBSIA-06A-K3 fans preheating zone bottom side switched
=HF+C1-9K1 =HF+C1/215.03 6ESÜB7D-40-00 preheating zone1-4 bottom side on
=HF+C1-9K2 =HF+C1/215.03 6ESÜB7D-40-00 preheating zone5-7 bottom side on
=HF+C1-9K3 =HF+C1/210.02 6ESÜB7D-40-00 switch onfan preheating zonebottom side switched
=HF+C1-9K10 =HF+C1/140.02 6ETEM2-3 Interf. Relais 24VDC 1 Wechsler thermocontrolbottom side OK
=HF+C1-9U1 =HF+C1/195.01 6ERELOMRON-3 preheating zone 1 bottom side
=HF+C1-9U2 =HF+C1/195.02 6ERELOMRON-3 preheating zone 2 bottom side
=HF+C1-9U3 =HF+C1/195.03 6ERELOMRON-3 preheating zone 3 bottom side
=HF+C1-9U4 =HF+C1/195.04 6ERELOMRON-3 preheating zone 4 bottom side
=HF+C1-9U5 =HF+C1/195.05 6ERELOMRON-3 preheating zone 5 bottom side
=HF+C1-9U6 =HF+C1/195.07 6ERELOMRON-3 preheating zone 6 bottom side
=HF+C1-9U7 =HF+C1/195.08 6ERELOMRON-3 preheating zone 7 bottom side
=HF+C1-9V3 =HF+C1/285.08 6ESÜ-ZT02 interference- unit
=HF+HM1-9B1 =HF+C1/160.01 140717 thermocouplepreheating zone 1bottom side
=HF+HM1-9B1.1 =HF+C1/180.01 83324 thermocouplepreheating zone 1bottom side
=HF+HM1-9B2 =HF+C1/160.02 140717 thermocouplepreheating zone 2bottom side
=HF+HM1-9B2.1 =HF+C1/180.02 83324 thermocouplepreheating zone 2bottom side
=HF+HM1-9B3 =HF+C1/160.03 140717 thermocouplepreheating zone 3bottom side
=HF+HM1-9B3.1 =HF+C1/180.03 83324 thermocouplepreheating zone 3bottom side
=HF+HM1-9B4 =HF+C1/160.04 140717 thermocouplepreheating zone 4bottom side
=HF+HM1-9B4.1 =HF+C1/180.04 83324 thermocouplepreheating zone 4bottom side
=HF+HM1-9B5 =HF+C1/160.05 140717 thermocouplepreheating zone 5bottom side
=HF+HM1-9B5.1 =HF+C1/180.05 83324 thermocouplepreheating zone 5bottom side
=HF+HM1-9B6 =HF+C1/160.07 140717 thermocouplepreheating zone 6bottom side HF3/20
=HF+HM1-9B6.1 =HF+C1/180.07 83324 thermocouplepreheating zone 6bottom side HF3/20
0 1 2 3 4 5 6 7 8 9
Page
=
DD
HF
=HF+DD/11
10
Modification Date
Name Norm
Check.
Proj.
Origin
Date
Crea. f.
ERSA
Hotflow 3/xx
18.06.2009
=HF+DD/9
133953-V00
Otto-Schott-Straße 5
97877 Wertheim
GmbH
Plant designation
Project name
14:15:1908.07.2010
+
file name (*.pdf)
133953-V00_100705
basic-project
-
Device list
Description
Device list
DIN_PSL_50_2_ERSA_LS1
Part numberPage/Path
=HF+HM1-9B7 =HF+C1/160.08 140717 thermocouplepreheating zone 7bottom side HF3/20
=HF+HM1-9B7.1 =HF+C1/180.09 83324 thermocouplepreheating zone 7bottom side HF3/20
=HF+HM1-9E1 =HF+C1/285.00 6HKRO400V-3.3KW heating preheating zone 1 bottom side
=HF+HM1-9E2 =HF+C1/290.00 6HKRO400V-3.3KW heating preheating zone 2 bottom side
=HF+HM1-9E3 =HF+C1/295.00 6HKRO400V-3.3KW heating preheating zone 3 bottom side
=HF+HM1-9E4 =HF+C1/300.00 6HKRO400V-3.3KW heating preheating zone 4 bottom side
=HF+HM1-9E5 =HF+C1/305.00 6HKRO400V-3.3KW heating preheating zone 5 bottom side
=HF+HM1-9E6 =HF+C1/310.00 6HKRO400V-3.3KW heating preheating zone 6 bottom side
=HF+HM1-9E7 =HF+C1/315.00 6HKRO400V-3.3KW heating preheating zone 7 bottom side
=HF+HM1-9M1 =HF+C1/285.05 6HZL-MOT144B fan preheating zone 1 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M2 =HF+C1/290.05 6HZL-MOT144B fan preheating zone 2 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M3 =HF+C1/295.05 6HZL-MOT144B fan preheating zone 3 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M4 =HF+C1/300.05 6HZL-MOT144B fan preheating zone 4 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M5 =HF+C1/305.05 6HZL-MOT144B fan preheating zone 5 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M6 =HF+C1/310.05 6HZL-MOT144B fan preheating zone 6 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+HM1-9M7 =HF+C1/315.05 6HZL-MOT144B fan preheating zone 7 bottom side
6HZL-MOT145 Lüftermotor Typ L7, 1450rpm
=HF+C1-10F1 =HF+C1/5.02 6EBSIA-63A-B3 prefuse 400VACheating zone 1-10 top
=HF+C1-10F2 =HF+C1/5.04 6EBSIA-63A-B3 prefuse 400VACheating zone 1-10 bottom side
=HF+C1-10F3 =HF+C1/5.06 6EBSIA-16A-B3 supply 400VACover emergency off
=HF+C1-11F1 =HF+C1/395.03 6EBSIA-06A-B1 supply pump hot-water-circuit
=HF+C1-11K1 =HF+C1/395.01 6ETEM2-3 water pump on hot-water-circuit
=HF+WC-11M1 =HF+C1/395.03 147511 pump hot-water-circuit
=HF+WC-11S1 =HF+C1/395.05 142939 water min advance warninghot-water-circuit
=HF+WC-11S2 =HF+C1/395.07 142939 water min hot-water-circuit
=HF+WC-11S3 =HF+C1/395.08 147646 Temperaturwächter G1/2" - 80°C thermo controlhot-water-circuit
=HF+C1-12K1 =HF+C1/390.07 6ETEM2-3 cold water cooling unit internal stop valve on
=HF+C1-12K2 =HF+C1/390.09 6ETEM2-3 cold water cooling unit externalstop valve on
=HF+WC-12S1 =HF+C1/390.01 6BO305 cooling unit pressure ok
=HF+WC-12Y1 =HF+C1/390.02 6X00050 stop valve internal 1
=HF+WC-12Y2 =HF+C1/390.03 6X00050 stop valve internal 2
=HF+WC-12Y3 =HF+C1/390.04 6X00050 stop valve external 1
0 1 2 3 4 5 6 7 8 9
Page
=
DD
HF
=HF+DD/12
11
Modification Date
Name Norm
Check.
Proj.
Origin
Date
Crea. f.
ERSA
Hotflow 3/xx
18.06.2009
=HF+DD/10
133953-V00
Otto-Schott-Straße 5
97877 Wertheim
GmbH
Plant designation
Project name
14:15:2008.07.2010
+
file name (*.pdf)
133953-V00_100705
basic-project
-
Device list
Description
Device list
DIN_PSL_50_2_ERSA_LS1
Part numberPage/Path
=HF+WC-12Y4 =HF+C1/390.06 6X00050 stop valve external 2
=HF+C1-13F1 =HF+C1/380.02 6EBSI4,0A-T 24VDC cold water cooling unit
37420
=HF+C1-13K1 =HF+C1/380.00 6ETEM2-3 cold water cooling unit internal on
=HF+WC-13A1 =HF+C1/380.02 153594 switch cabinet cold water cooling unit internal
=HF+C1-14K1 =HF+C1/385.00 6ETEM2-3 cold water cooling unitexternal on
=HF+C1-15F1 =HF+C1/10.02 6EBSIA-20A-K1 main switch on ups
=HF+C1-15G1 =HF+C1/10.01 6ENETZT020 Geregelte Stromversorgung, 320-575 V // supply at ups
=HF+C1-15G2 =HF+C1/10.01 70588
ups
=HF+C1-15G3 =HF+C1/10.03 70545 battery modul
=HF+C1-15K1 6ESÜB7D-40-00 main switch on ups
=HF+C1-15KT1 64839 switch off battery-unit
=HF+C1-16F1 =HF+C1/400.01 6EBSI4,0A-T supply temperature-management
37420
=HF+E1-16Y1 =HF+C1/400.02 157156 Proportionaldruckregelventil pressure control valve temperature-management 1
=HF+E1-16Y2 =HF+C1/400.04 157156 Proportionaldruckregelventil pressure control valve temperature-management 2
=HF+E1-16Y3 =HF+C1/400.06 157156 Proportionaldruckregelventil pressure control valve temperature-management 3
=HF+E1-16Y4 =HF+C1/400.07 157156 Proportionaldruckregelventil pressure control valve temperature-management 4
=HF+E1-16Y5 =HF+C1/400.02 157156 Proportionaldruckregelventil pressure control valve temperature-management 5
=HF+E1-16Y6 =HF+C1/400.04 157156 Proportionaldruckregelventil pressure control valve temperature-management 6
=HF+E1-16Y7 =HF+C1/400.06 157156 Proportionaldruckregelventil pressure control valve temperature-management 7
=HF+E1-16Y8 =HF+C1/400.07 157156 Proportionaldruckregelventil pressure control valve temperature-management 8
=HF+E1-19A1 =HF+C1/505.07 189806 Desktop-PC, Windows 7 desktop pc
198292 Desktop-PC, Windows 7 mit RAID1
199336 Ersatzfestplatte Desktop PC (RAID1)
=HF+E1-19A2.1 =HF+C1/20.03 145113 keyboard
145114
=HF+E1-19A2.2 =HF+C1/20.04 144054 Trackball
=HF+E1-19A3 =HF+C1/20.07 142409
ups
=HF+E1-19A4 =HF+C1/20.03 140429
monitor
141360
=HF+E1-19A5 =HF+C1/20.02 30247 modem
=HF+E1-19A6 =HF+C1/20.00 109933 USB/Ethernet
=HF+E1-19A10 =HF+C1/900.06 control-panel
=HF+C1-21F1 =HF+C1/115.07 37420 supplyexhaust-air-flap
6EBSI2,5A-T Sicherung-G 2.5AT
=HF+C1-21K1 =HF+C1/115.01 6ETEM2-3 exhaust air on
=HF+E1-21B1 =HF+C1/115.04 6EBG00002 pressure switch exhaust air infeed
0 1 2 3 4 5 6 7 8 9