00193756-03.pdf - 第26页

Retrofit instructions Nozz le changer SIPLAC E HF-series C &P head 26 : Attach the cable for the p ower supp ly to the nozz le. 2 : Scr ew the nozz le chan ger on wit h four M5x12 screws. 2

100%1 / 30
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
12/2004 Edition
25
: Place the nozzle changer onto the newly fitted carrier with the top facing downwards.
: Connect the compressed air hose to the new nozzle changer.
2
2
The wiring should look like this: 2
2
2
2
2
2
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
26
: Attach the cable for the power supply to the nozzle.
2
: Screw the nozzle changer on with four M5x12 screws.
2
Retrofit instructions Nozzle changer SIPLACE HF-series C&P head
12/2004 Edition
27
Mounting the third row of nozzle changers 2
This nozzle changer is installed in the same way as the first row but without nozzle reject.Use
package 00119663-01 nozzle changer 2 HF 12 segment C&P head or 0011964-01 nozzle
changer 2 HF 6 segment C&P head. In this case the extension is not needed. 2
2
: Switch the placement system on again at the main switch.
: Perform a functional test.
2