JO-103-002_w.pdf - 第42页

2-5 AL VEG-ID 1.1.3 Procedure for Detachment of Fixtures Procedure (1) Detach the xtures for both Y and X axes. Fixture for Y Axis Fixture for X Axis Screw (M4) Screw (M3) Screw (M3) Fig. B7 (2) Fix the clamp plate (acc…

100%1 / 137
2-4
ALVEG-ID
(4) Fasten the cables with tie wraps.
Adjust the tie wraps to the location of the tie mounts and x them on
the tie mounts after tightening the cable ties.
Tie Mount
Bundle
Fig. B5
The cameral cable should also be bundled and xed on the tie mounts
using the tie wraps.
Camera Cable
Fig. B6
0809-002
1.1 Procedures for Attachment of Camera Unit and Detachment of Fixtures
2-5
ALVEG-ID
1.1.3 Procedure for Detachment of Fixtures
Procedure
(1) Detach the xtures for both Y and X axes.
Fixture for Y Axis
Fixture for X Axis
Screw (M4)
Screw (M3)
Screw (M3)
Fig. B7
(2) Fix the clamp plate (accessory) with the screws (M3) that were used to
fasten the xtures and tighten the clamp screw for rm attachment.
X Axis
Y Axis
Clamp Screw
Clamp Screw
Clamp Plate
Screw (M3)
Fig. B8
0809-002
1.1 Procedures for Attachment of Camera Unit and Detachment of Fixtures
2-6
ALVEG-ID
(3) Detach the camera end protection cap located inside the LED lighting
unit.
Protection Cap
Fig. B9
No image can be captured with the protection cap attached.
0809-002