1.4.3 Cleaning of V acuum Nozzle Periodically perform cleaning of vacuum nozzles to maintain reliable and stable component picks and placement. • It is advisable that the nozzle be cleaned at least once a week. • Change …

100%1 / 299
1.4.2 Filter Replacement of Head Section
(1) Detachment of Filter Holder
Pull out the filter holder forward.
Fig. 4A61
(2) Replacement of Filters
Detach two filters sideways and replace them with new ones.
Fig. 4A62
(3) Attachment of Filter Holder
Direct Cut-Off Side D upward and insert the filter holder fully until it
stops.
0110-003 1-46 AFO01ETRP
1.4 Maintenance Method
1.4.3 Cleaning of Vacuum Nozzle
Periodically perform cleaning of vacuum nozzles to maintain reliable
and stable component picks and placement.
It is advisable that the nozzle be cleaned at least once a week.
Change cleaning frequency according to varying frequency of use
and stain degree along with certain environmental conditions.
When the vacuum suction force weakens or a nozzle failure in com-
ponent pick or placement occurs, it is required to check the stain
degree and clean the nozzle.
Fig. 4A63
Cleaning Method
(1) Detach the vacuum nozzle.
(2) Blow air to remove dust and dirt. At this time, use clean, dry, and
non-lubricated air. For heavily stained nozzles, use an ultrasonic
cleaner.
(3) Attach the vacuum nozzle.
(a) Refer to “1.4.4 Detachment and Attachment of Vacuum
Nozzle” for detailed information of detachment and
attachment procedures.
(b) Detach the nozzle before demagnetizing it.
Keep the head section free of any magnetic field.
As an example,
Do not bring a magnet close to the head section.
Do not bring the demagnetizer to the head section.
Note
01 10-003 1-47 AFO01ETRP
1.4 Maintenance Method
1.4.4 Detachment and Attachment of Vacuum Nozzle
The vacuum nozzles must be detached or attached
with the operation power being turned “ON”
It is dangerous. Be sure to detach or attach a vacuum
nozzle alone (without any other attended personnel).
Before detaching or attaching a vacuum nozzle, be
sure to spread a rag under the working area.
Otherwise, a fallen vacuum nozzle will easily be lost if
any.
To facilitate the detachment or the attachment of the vacuum nozzle,
move the X/Y table in the X (plus) direction to leave a space under the
placement station.
Use the [Table X] button in the “Others” tab sheet to move the
X/Y table. (Operation Sequence: “MNL OPN.” Window
(Submenu) Æ “Manual Axis Opn” Tab Æ “Others” Tab Æ
[Table X] Button).
(1) Detachment of Vacuum Nozzle
(1-1) Set the [OPERATION] switch to the “SETUP” side.
Confirm that the “LOCK” lamp on the front operation panel is
“ON”
0110-003 1-48
AFO01ETRP
1.4 Maintenance Method
CAUTION
CAUTION
Note