6.6 P783 Jumper Setting List SERVICE MANUAL SPF 6.6−1 D54SEC−85−040−B0 6.6 P783 Jumper Setting List D54SEC−85−040−B0 Sentence No. MMI JA−M00105 1/4 Jumper setting contents No. Functions Contents Settings JP1 FD select OF…

100%1 / 160
SPF
6.5 SC Timer Table
SERVICE MANUAL
6.5−2
D54SEC−85−030−B0
No. RemarksSC address
Setting
value
Name
TM33
Parts transfer detection OFF
(Carrying out)
0.10 5340
TM34 Not used 0.30 5341 Correspond to closed head
TM35
Cleaner nozzle ascend / descend
error
1.00 5342
TM36 Resolvent dispensing timer 0.06 5343
Resolvent dispensing total
time
TM37
Squeegee stop time timer
(Count except while printing)
60.00 5344
Set value ´ count of No.10 in
counter table (*1)
TM38
Resolvent dispensing completion
® to paper feed
0.50 5345
TM39 Interval time between valve ON 0.10 5346
TM40
Ring blow low speed ® high speed
rotation changeover timer
(energy−saving type)
0.20 5347
TM41
After vacuum OFF of cleaner
vacuum, cleaner nozzle descent
timer
1.50 5350
TM42
Rear stopper descent detection
time−up
5.00 5351 Correspond to closed head
TM43
Front stopper descent detection
time−up
5.00 5352 Correspond to closed head
TM44
The time until SST axis moves
from reference pin valve set
0.20 5353 Valid when pin positioning
TM45 Not used 0.20 5354
TM46 Not used 0.20 5355
TM47 Not used 0.20 5356
TM48 Stop timer after printing 0.00 5357
=HINT=
*1 : SPF counter setting table
No.
Name
Setting
value
SC address Remarks
10
Squeegee stop time timer
(Count except while printing)
20 5369 TM37 ´ setting count (sec.)
6.6 P783 Jumper Setting List
SERVICE MANUAL
SPF
6.6−1
D54SEC−85−040−B0
6.6 P783 Jumper Setting List
D54SEC−85−040−B0
Sentence No.
MMI JA−M00105 1/4
Jumper setting contents
No. Functions Contents Settings
JP1 FD select
OFF : 2HD
ON : 2DD
OFF 2HD
JP2 CCLK
OFF : Ineffective
ON : Effective
OFF Ineffective
JP3 BCLK
OFF : Ineffective
ON : Effective
OFF Ineffective
1−16 ON INT0 OFF
2−15 ON INT1 OFF
Interrupt
level
to
PanaBus
of
2
port
RAM
3−14 ON INT2 OFF
JP4
Interr
u
pt
le
v
el
to
PanaB
u
s
of
2
port
RAM
interrupt
4−13 ON INT3 OFF
INT5
JP4
interrupt
All
OFF
at
master
5−12 ON INT4 OFF
INT5
All OFF at master
6−11 ON INT5 ON
7−10 ON INT6 OFF
8− 9 ON INT7 OFF
SPF
6.6 P783 Jumper Setting List
SERVICE MANUAL
6.6−2
D54SEC−85−040−B0
MMI JA−M00105 2/4
Jumper setting contents
No. Functions Contents Settings
JP5
AVE to PanaBus
(Effective at slave)
OFF : Ineffective
ON : Effective
ON Effective
JP6
AVE from PanaBus
(Effective at master)
OFF : Ineffective
ON : Effective
OFF Ineffective
JP7 Backup battery
OFF : Ineffective
ON : Effective
ON Effective
JP8
Watchdog time changeover
(if reset,1.6s for both ON&OFF)
OFF : 1.6s
ON : 100ms
OFF 1.6s
JP9
READY
signal
1−2 ON : Ineffective OFF
E
f
f
e
c
t
i
v
e
JP9
READY
s
i
gna
l
1−3 ON : Effective ON
E
f
f
ec
t
i
v
e
JP10 RAM 0/1 WAIT
OFF : 1Wait
ON : 0Wait
OFF
1
Wait
JP11 ROM 2/3 WAIT
OFF : 3Wait
ON : 2Wait
OFF
3
Wait
JP12 Watchdog
OFF : Ineffective
ON : Effective
OFF Ineffective
JP13
NA signal
1−2 ON : Effective OFF
Inef
fective
JP13
NA
signal
(Set to ineffective)
1−3 ON : Ineffective ON
I
ne
f
f
ec
ti
ve
JP14
1MB 2MB 4MB
JP14
JP15
ROM select
ON OFF ON ON
4MB
JP15
ON ON OFF OFF
JP16 PanaBus allocation
OFF
8000 : 0 B000 : FFFF
ON
8000 : 0 9000 : FFFF
ON 0 9000
JP17
T
ime
out
interrupt
1−2 ON : Effective ON
E
f
f
e
c
t
i
v
e
JP17
T
i
me ou
t
i
n
t
errup
t
1−3 ON : Ineffective OFF
E
f
f
ec
t
i
v
e
JP18
INT
0
setting
1−2 ON : PanaBus
(at master)
OFF
2−
p
ort
JP18
INT
0
se
tti
ng
1−3 ON : 2−port RAM
(at slave)
ON
2 port
RAM
0JP19
T
ime
out
A
VE
1−2 ON : Effective ON
E
f
f
e
c
t
i
v
e
0JP19
T
i
me ou
t
A
VE
1−3 ON : Ineffective OFF
E
f
f
ec
t
i
v
e
JP20
2 port
RAM
address
seen
from
PanaBus
1−2 ON
8000 : 0000−8000 : 7FFF
ON
0000
JP20
2
−por
t
RAM
a
dd
ress seen
f
rom
P
ana
B
us
1−3 ON
8000 : 8000−8000 : FFFF
OFF
0000
8000